PDMG-RH Gen3 UHF partial discharge monitoring system for GIS, up to 2000 sensors

The PDMG-RH Gen3 is a permanent partial discharge monitoring system for gas insulated switchgear (GIS) that uses UHF sensors and is certified to IEC 61850. It serves up to 2000 UHF partial discharge sensors and up to 4000 gas density sensors.

UHF partial discharge sensors
up to 2000
Gas density sensors
up to 4000
Frequency band
300–2000 MHz
Sensitivity
−80 dBm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The bandwidth is 300–2000 MHz with a sensitivity of −80 dBm and a dynamic range of 70 dB. The standard optical unit, OCU, works in the 300–1500 MHz band with a range of −75 to −30 dBm, while the HDR OCU works across 300–2000 MHz with a range of −80 to −10 dBm. The RDC unit has 7 UHF channels, six for sensor inputs and one for an external antenna, and it accepts voltage transformer signals and switching signals. The optional Arc Monitor software uses the UHF sensors already installed to detect and locate arc flashovers, so healthy sections can be re-energised more quickly.

Internal or external UHF sensors pick up partial discharge signals. Each channel has its own filter and gain control: band-pass or programmable filters, gating, coincidence filtering and notch filtering. Data goes to the Expert program, where a neural network separates noise and assigns the signal to one of six types of GIS defect with a confidence level: protrusion on the conductor, protrusion on the enclosure, floating parts with poor electrical contact, free particles, cavities between screens and insulation, and voids and tree-like breakdowns in the insulation. Together with amplitude, discharge frequency and trend, this forms the basis for risk assessment.

Control is handled from a central computer with a backup system, a 21.5 inch screen, keyboard and mouse. Timestamps come from NTP over the local network or from GPS, and data is kept on solid-state storage for up to 5 years. The unit provides 3 standard SCADA or SCS alarm contacts and 5 more that can be configured, plus 8 status LEDs, a remote Ethernet client, and data and alarm reporting through IEC 61850 and Modbus. It runs from 110 V at 50/60 Hz and 250 mA, operates from −25 to 55 °C at humidity up to 100 % including condensing conditions, and the equipment is tested for immunity and emissions against industrial standards at raised levels.

Partial discharge is an early indicator of most causes of GIS failure, so continuous monitoring under operating voltage is the basis of condition-based maintenance. The system is installed at high-voltage substations, power stations and critical industrial sites, is suitable for upgrading existing installations, and is compatible with GIS from most leading manufacturers.

Technical specifications

UHF partial discharge sensorsup to 2000
Gas density sensorsup to 4000
Frequency band300–2000 MHz
Sensitivity−80 dBm
Dynamic range70 dB
Standard OCU300–1500 MHz, −75…−30 dBm
HDR OCU300–2000 MHz, −80…−10 dBm
RDC inputs7 UHF channels (6 sensors + 1 external antenna)
Filteringband-pass or programmable, gating, coincidence, notch
Alarms3 standard SCADA/SCS + 5 configurable
External interfacesEthernet, IEC 61850, Modbus
Indication8 status LEDs
Time syncNTP over LAN or GPS
Data storageSSD, up to 5 years
Power supply110 V 50/60 Hz, 250 mA
Operating temperature−25…55 °C
Humidityup to 100 % with condensation

Part numbers

Show all part numbers (1)

PDMG - RH - Gen 3

Request a price and lead time

PDMG-RH Gen3 UHF partial discharge monitoring system for GIS, up to 2000 sensors. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the system be installed on existing GIS from another manufacturer?

Yes, the system suits upgrades and is compatible with GIS from most leading manufacturers, working with internal and external UHF sensors.

How does the system send alarms to SCADA?

Through 3 standard and 5 configurable alarm contacts, with data and alarm reporting over IEC 61850 and Modbus.

Can the system locate an arc flashover?

Yes, with the Arc Monitor software option, which uses the UHF sensors already installed.