Online dissolved gas monitor for transformer oil, hydrogen and moisture

A fixed dissolved gas analysis (DGA) monitor for power transformers that continuously measures hydrogen and dissolved water in insulating oil. It picks up developing faults at an early stage, holds stable readings at low concentrations, and can be installed on site in under 2 hours.

Type
online dissolved gas analysis (DGA) monitor, detection tier
Measured parameters
hydrogen, moisture (dissolved water)
Monitored equipment
power transformers and other oil-immersed electrical equipment
Communication protocols
DNP3, Modbus, IEC 61850 (option)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The monitor belongs to the detection tier of the online DGA range and is intended for power transformers and other oil-immersed electrical equipment. Hydrogen is the primary gas for spotting developing faults, so measuring it continuously and without cross-sensitivity to other gases gives early warning of damage. Parallel moisture monitoring makes it possible to relate water content to transformer loading and to follow long-term trends.

The unit has built-in oil circulation with flow monitoring, continuous conditioning of the housing and oil, and vacuum tolerance. Moisture and solubility coefficients for all common insulating liquids are stored in memory, so water content is converted correctly for mineral and other oils. The communication electronics are designed for substation conditions.

Data is delivered over DNP3 and Modbus, while IEC 61850 is available as an option. Monitors connect easily into a network, so one system can cover a whole substation or a large transformer fleet at modest cost per measuring point. Used together with a portable dissolved gas analyser from the same product family, the monitor becomes part of a management programme for critical transformers.

The monitor can stay in service during oil drying and degassing, so it does not have to be removed while a live transformer is being treated. Maintenance is minimal, and hydrogen readings stay stable at the low concentration levels where defects start to be detected.

The same range also includes model 2, which adds carbon monoxide measurement to follow degradation of cellulose, and diagnostic chromatographic models 5 and 9. Model 5 measures the five gases of the Duval triangle plus moisture, while model 9 performs a full dissolved gas analysis together with oxygen and nitrogen. The choice between detection and diagnostic tiers depends on how critical the transformer is and how deep the diagnosis needs to be.

Technical specifications

Typeonline dissolved gas analysis (DGA) monitor, detection tier
Measured parametershydrogen, moisture (dissolved water)
Monitored equipmentpower transformers and other oil-immersed electrical equipment
Communication protocolsDNP3, Modbus, IEC 61850 (option)
Oil circulationbuilt-in, with flow monitoring
Conditioningcontinuous, housing and oil
Vacuum toleranceyes
Insulating liquidsbuilt-in moisture and solubility coefficients for all common liquids
Communication electronicsdesigned for substations
Installation timeunder 2 hours

Request a price and lead time

Online dissolved gas monitor for transformer oil, hydrogen and moisture. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the monitor be connected to a substation SCADA system?

Yes, the monitor supports DNP3 and Modbus, and IEC 61850 is available as an option. Several monitors can be networked to cover the whole substation.

Does the monitor need to be removed during oil drying or degassing?

No, the monitor is compatible with oil drying and degassing and tolerates vacuum.

How does this model differ from models 5 and 9?

This model measures only hydrogen and moisture and belongs to the detection tier. Models 5 and 9 are diagnostic, using chromatographic analysis to determine the five Duval triangle gases or the full dissolved gas composition.