Modus / Modus Slim2 / Modus mini — electronic gas volume correctors (PTZ) with a modem
Modus, Modus Slim2 and Modus mini are electronic gas volume correctors that convert the operating volume measured by the meter to standard conditions using pressure, temperature and the compressibility factor. They have a built-in communication module and are certified to MID (MI-002) and ATEX. For custody transfer gas metering.
- Type
- electronic PTZ gas volume corrector (EVC) with data logging and a built-in modem
- Modus
- 2 independent PTZ channels; LF up to 3 Hz, second channel also HF up to 5 kHz; additional analog inputs
- Modus Slim2
- 1 PTZ channel, GSM/GPRS, UNI TS 11291-3 (CTR) protocol; ATEX II 1 G Ex ia IIA T3 Ga
- Modus mini
- 1 channel; 2G/Cat-M1/NB-IoT modem; DLMS/COSEM + UNI TS 11291-14; ATEX II 2G Ex ib IIC T4 Gb; metrology battery 15 years
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The corrector receives pulses from the gas meter, measures pressure with a piezoresistive absolute pressure sensor with an error below 0.25 %, and measures temperature with a class A PT1000 sensor. The pressure sensor ranges run from 0.6–2 to 20–80 bar (abs.), including 0.8–2, 0.6–3.5, 0.9–10, 5–24 and 10–40 bar (abs.). The compressibility factor is calculated per ISO 12213-2 (AGA8-DC92), ISO 12213-3 (SGERG-88) or AGA NX-19, and the correction factor per EN 12405. All models are intended for metering at gas distribution stations, industrial and commercial sites, district stations and biomethane production plants. All models are certified to MID (annex MI-002) and ATEX and have a built-in communication module.
Modus is a two-channel corrector with data logging. It has two independent PTZ channels and an LF pulse input up to 3 Hz, the second channel also accepts HF signals up to 5 kHz, and there are additional inputs for station monitoring. It may be installed in hazardous zone 0. It is controlled remotely from SCADA systems via the Modbus and UNI TS 11291-3 (CTR) protocols and runs on a battery for more than 5 years, and for permanent communication it can be powered from the MPower intrinsically safe barrier (mains, solar panel, microturbine).
Modus Slim2 is a single-channel corrector with integrated sensors and a GSM/GPRS modem, using the UNI TS 11291-3 (CTR) protocol. The IP66 polycarbonate housing measures 180×150×40 mm, and the explosion protection is II 1 G Ex ia IIA T3 Ga. The battery can be replaced in the hazardous area without breaking the metrological seal.
Modus mini is a compact single-channel corrector for commercial and industrial consumers. It has a 2G/LTE Cat-M1/NB-IoT modem, the DLMS/COSEM and UNI TS 11291-14 protocols, a graphic display, an optical port per EN 62056-21, IP66 protection and the II 2G Ex ib IIC T4 Gb version. The metrological battery lasts up to 15 years and the modem battery up to 5 years with one session per day. The SGERG-mod-H2 formula per DVGW G 685-6 is supported, so the device is suitable for hydrogen blends up to 20 %. The correctors are configured with the Modus Configurator software.
Technical specifications
| Type | electronic PTZ gas volume corrector (EVC) with data logging and a built-in modem |
|---|---|
| Modus | 2 independent PTZ channels; LF up to 3 Hz, second channel also HF up to 5 kHz; additional analog inputs |
| Modus Slim2 | 1 PTZ channel, GSM/GPRS, UNI TS 11291-3 (CTR) protocol; ATEX II 1 G Ex ia IIA T3 Ga |
| Modus mini | 1 channel; 2G/Cat-M1/NB-IoT modem; DLMS/COSEM + UNI TS 11291-14; ATEX II 2G Ex ib IIC T4 Gb; metrology battery 15 years |
| Pressure sensor | piezoresistive, error <0.25 %; ranges 0.6–2 … 20–80 bar (abs.) |
| Temperature sensor | PT1000 class A |
| Compressibility formulas | ISO 12213-2 (AGA8-DC92), ISO 12213-3 (SGERG-88), AGA NX-19; Modus mini also SGERG-mod-H2 (DVGW G 685-6) |
| Temperature | −25…+60 °C (Modus mini up to +70 °C) |
| Power supply | lithium battery (more than 5 years with daily communication); Modus external power via MPower |
| Standards | EN 12405-1/-2, MID 2014/32/EU (MI-002), ATEX 2014/34/EU |
Request a price and lead time
Modus / Modus Slim2 / Modus mini — electronic gas volume correctors (PTZ) with a modem. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which formulas does the corrector use for the compressibility factor?
ISO 12213-2 (AGA8-DC92), ISO 12213-3 (SGERG-88) or AGA NX-19, and Modus mini also SGERG-mod-H2 (DVGW G 685-6).
What pressure ranges and error do the sensors have?
The piezoresistive sensor has an error below 0.25 % and ranges from 0.6–2 to 20–80 bar (abs.), including 5–24 and 10–40 bar (abs.).
How do Modus, Modus Slim2 and Modus mini differ in channels and explosion protection?
Modus has two PTZ channels and is approved for zone 0, Slim2 is single-channel and marked II 1 G Ex ia IIA T3 Ga, and mini is single-channel with II 2G Ex ib IIC T4 Gb.