Calisto 5 Online DGA Diagnostic Monitor for Five Fault Gases and Moisture
Multi-gas online monitor for power transformers that uses gas chromatography to measure hydrogen, carbon monoxide, methane, acetylene, ethylene and moisture. It supports continuous Duval Triangle diagnosis and picks up arcing at the earliest onset.
- Type
- online dissolved gas analysis (DGA) diagnostic monitor
- Measurement method
- gas chromatography
- Gases measured
- hydrogen, carbon monoxide, methane, acetylene, ethylene
- Moisture
- yes
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The Calisto 5 is a multi-gas online monitor for assessing the condition of power transformers and other oil-filled electrical equipment. It measures five of the gases on the Duval Triangle, so early hydrogen detection is joined by continuous classification of the fault type, whether discharge, arcing or overheating. Acetylene is measured from 0.2 ppm, which means arcing can be seen from the moment it starts.
Measurement relies on gas chromatography, a physical separation method in which the components of a mixture are spread between a stationary phase and a mobile phase that moves in one direction. The monitor uses a proprietary chromatographic method, and its readings agree with laboratory data over both the short and the long term.
The unit calibrates itself automatically against certified primary grade reference gas. A front-panel display presents the data and status of the monitor on site, so no tools or computer are needed to read it. Oil circulation with flow monitoring is built in, the enclosure and the oil are conditioned continuously, and the device tolerates vacuum. Moisture and solubility coefficients for all common insulating fluids are stored in the monitor.
Data is sent over DNP3 and Modbus, with IEC 61850 available as an option, and the communication electronics are hardened for substation use. Installation accessories include a mounting rack, stainless steel hoses, isolating valves for oil lines, 3/8 OD copper tubing, an external mounting kit, protective earthing and an oil temperature sensor. Within the range, the detection models register only hydrogen, moisture and carbon monoxide, while the Calisto 9 gives a complete analysis including oxygen and nitrogen, which places the Calisto 5 in the middle.
Technical specifications
| Type | online dissolved gas analysis (DGA) diagnostic monitor |
|---|---|
| Measurement method | gas chromatography |
| Gases measured | hydrogen, carbon monoxide, methane, acetylene, ethylene |
| Moisture | yes |
| Acetylene | from 0.2 ppm |
| Calibration | automatic, using certified primary reference gas |
| Display | front-panel display |
| Communication protocols | DNP3, Modbus, IEC 61850 (optional) |
| Oil circulation | built-in, with flow monitoring |
| Conditioning | continuous, enclosure and oil |
| Vacuum tolerance | yes |
| Equipment monitored | power transformers and other oil-filled electrical equipment |
Request a price and lead time
Calisto 5 Online DGA Diagnostic Monitor for Five Fault Gases and Moisture. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the acetylene detection threshold on the Calisto 5?
Acetylene is measured from 0.2 ppm, so arcing is picked up from the moment it begins.
How is the monitor calibrated?
It calibrates itself automatically against certified primary grade reference gas.
Can the readings be checked without a laptop?
Yes. The front-panel display shows the data and status of the monitor on site, so no tools or computer are needed.