International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Calisto 5 Online DGA Diagnostic Monitor for Five Fault Gases and Moisture

Multi-gas online monitor for power transformers that uses gas chromatography to measure hydrogen, carbon monoxide, methane, acetylene, ethylene and moisture. It supports continuous Duval Triangle diagnosis and picks up arcing at the earliest onset.

Type
online dissolved gas analysis (DGA) diagnostic monitor
Measurement method
gas chromatography
Gases measured
hydrogen, carbon monoxide, methane, acetylene, ethylene
Moisture
yes

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The Calisto 5 is a multi-gas online monitor for assessing the condition of power transformers and other oil-filled electrical equipment. It measures five of the gases on the Duval Triangle, so early hydrogen detection is joined by continuous classification of the fault type, whether discharge, arcing or overheating. Acetylene is measured from 0.2 ppm, which means arcing can be seen from the moment it starts.

Measurement relies on gas chromatography, a physical separation method in which the components of a mixture are spread between a stationary phase and a mobile phase that moves in one direction. The monitor uses a proprietary chromatographic method, and its readings agree with laboratory data over both the short and the long term.

The unit calibrates itself automatically against certified primary grade reference gas. A front-panel display presents the data and status of the monitor on site, so no tools or computer are needed to read it. Oil circulation with flow monitoring is built in, the enclosure and the oil are conditioned continuously, and the device tolerates vacuum. Moisture and solubility coefficients for all common insulating fluids are stored in the monitor.

Data is sent over DNP3 and Modbus, with IEC 61850 available as an option, and the communication electronics are hardened for substation use. Installation accessories include a mounting rack, stainless steel hoses, isolating valves for oil lines, 3/8 OD copper tubing, an external mounting kit, protective earthing and an oil temperature sensor. Within the range, the detection models register only hydrogen, moisture and carbon monoxide, while the Calisto 9 gives a complete analysis including oxygen and nitrogen, which places the Calisto 5 in the middle.

Technical specifications

Typeonline dissolved gas analysis (DGA) diagnostic monitor
Measurement methodgas chromatography
Gases measuredhydrogen, carbon monoxide, methane, acetylene, ethylene
Moistureyes
Acetylenefrom 0.2 ppm
Calibrationautomatic, using certified primary reference gas
Displayfront-panel display
Communication protocolsDNP3, Modbus, IEC 61850 (optional)
Oil circulationbuilt-in, with flow monitoring
Conditioningcontinuous, enclosure and oil
Vacuum toleranceyes
Equipment monitoredpower transformers and other oil-filled electrical equipment

Request a price and lead time

Calisto 5 Online DGA Diagnostic Monitor for Five Fault Gases and Moisture. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the acetylene detection threshold on the Calisto 5?

Acetylene is measured from 0.2 ppm, so arcing is picked up from the moment it begins.

How is the monitor calibrated?

It calibrates itself automatically against certified primary grade reference gas.

Can the readings be checked without a laptop?

Yes. The front-panel display shows the data and status of the monitor on site, so no tools or computer are needed.