Online DGA monitor model 2 for transformer oil, hydrogen, moisture and carbon monoxide

A detection-tier online dissolved gas monitor for power transformers that adds independent carbon monoxide measurement to hydrogen and moisture. It combines early fault detection through hydrogen with monitoring of cellulose insulation degradation.

Type
online dissolved gas analysis (DGA) monitor, detection tier
Measured parameters
hydrogen, moisture, carbon monoxide
Monitored equipment
power transformers and other oil-immersed electrical equipment
Supported protocols
DNP3.0, MODBUS (standard), IEC 61850 (option)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Model 2 is intended for power transformers and other oil-immersed electrical equipment. Dissolved hydrogen is the main gas for spotting developing faults at the earliest stage, while carbon monoxide is generated in large amounts when cellulose overheats. Measuring both gases at once reveals electrical and thermal faults as well as accelerated ageing of solid insulation, so staff receive warning early in the development of a fault.

Hydrogen and moisture readings remain stable, and the carbon monoxide channel operates independently of them. The unit includes built-in oil circulation with flow monitoring, continuous conditioning of the housing and oil, vacuum tolerance, and stored moisture and solubility coefficients for all common insulating liquids. The communication electronics are designed for substation conditions.

As standard, the monitor offers DNP3.0 and MODBUS protocols, so it fits into existing communication networks and SCADA systems. IEC 61850 is available as an option. The monitor signals its own faults and insufficient oil circulation, so the operator can see when the data no longer matches the condition of the transformer.

Installation and commissioning are straightforward. If a transformer later needs deeper diagnosis, model 2 can be replaced by diagnostic model 5 or 9 from the same range, which perform chromatographic analysis of several gases.

Model 2 suits sites where, alongside early fault detection, the condition of paper insulation must be followed and maintenance planned on the actual state of the transformer. The monitor's data supports well-founded maintenance decisions.

Technical specifications

Typeonline dissolved gas analysis (DGA) monitor, detection tier
Measured parametershydrogen, moisture, carbon monoxide
Monitored equipmentpower transformers and other oil-immersed electrical equipment
Supported protocolsDNP3.0, MODBUS (standard), IEC 61850 (option)
Oil circulationbuilt-in, with flow monitoring
Conditioningcontinuous, housing and oil
Vacuum toleranceyes
Insulating liquidsbuilt-in moisture and solubility coefficients for all common liquids
Self-monitoringalarm for monitor fault and low oil circulation
Communication electronicsdesigned for substations

Request a price and lead time

Online DGA monitor model 2 for transformer oil, hydrogen, moisture and carbon monoxide. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Why measure carbon monoxide in transformer oil?

Carbon monoxide is generated in large amounts when cellulose insulation overheats, so a rise in it indicates accelerated ageing of the solid insulation.

Which communication protocols come as standard?

DNP3.0 and MODBUS are standard, and IEC 61850 is ordered as an option.

Can the monitor be upgraded to a diagnostic model later?

Yes, model 2 can be replaced by model 5 or 9 from the same range if the transformer needs chromatographic diagnosis of several gases.