GISNOVA SF6 monitoring system for HV GIS, covering partial discharge, SF6 gas and circuit breakers

GISNOVA SF6 is a modular monitoring system for high voltage gas insulated switchgear, combining partial discharge, SF6 gas and circuit breaker monitoring on one platform. It suits both new and existing GIS installations.

Monitored parameters
partial discharges, SF6 gas, circuit breakers
SF6 gas
density, leakage, dew point
Circuit breaker
opening and closing times, coil current, fault current, velocity, position, motor and heater current, battery voltage, I2t sum
PD Hub channels
3, expandable to 6 or 12

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

GISNOVA SF6 is used at substations with high and extra high voltage gas insulated switchgear (GIS) as operators move from time-based to condition-based maintenance. GIS faults arise from manufacturing errors, damage in transport, installation mistakes, moisture ingress, SF6 leaks, and faults in the circuit breaker, its battery or its drive motor. Harmful partial discharges come from moving particles, protrusions and scratches on electrodes, particles on insulation surfaces, floating electrodes and voids in solid insulation. The approach follows the non-intrusive condition assessment methods of working group A3.32 of CIGRE and CIRED.

The system monitors partial discharges, SF6 gas and circuit breakers. For SF6 it tracks density, leakage and dew point. For circuit breakers it records opening and closing times, coil current, fault current, velocity, position, motor and heater current, battery voltage and the I2t sum. Trends are built for every parameter, and early warnings are generated.

The main elements are the PD Hub MKII unit, the EDS MKII circuit breaker data unit weighing about 2 kg, the sensors, and a central unit in a 42U-19” rack with monitoring software that shows real time data and trends. The PD Hub has 3 channels, expandable to 6 or 12, with 125 MS/s sampling and 12 bit resolution. Its steel housing is finished in RAL 7035 paint and has IP 65 protection. Dimensions are 600x600x221 mm and weight about 35 kg for the 3 and 6 channel versions, and 800x800x250 mm and about 50 kg for the 12 channel version. Power draw is 50 W at most, from 220 VAC 50/60 Hz.

The PD Scope module covers 16 kHz to 30 MHz, extendable to 1 GHz, with 10 bit resolution, 50 Ω impedance and record times from 1 μs to 20 μs. Partial discharge sensors include UHF horn and spiral antennas, internal UHF sensors and HFCT sensors, and SF6 gas sensors are added. Communication runs over fibre optic with ST connectors, Ethernet RJ45 and RG223 or RG214 coaxial cable, using DNP3, MODBUS, OPC UA and TCP/IP, together with the IEC 61850 and IEC 60870-5-104 standards.

Operating temperature is +5°C to +50°C in the standard version, -20°C to +50°C with heating, +5°C to +65°C with cooling, and -20°C to +65°C with both. The system is adapted to each piece of equipment after a site survey and integrates with existing control systems.

Technical specifications

Monitored parameterspartial discharges, SF6 gas, circuit breakers
SF6 gasdensity, leakage, dew point
Circuit breakeropening and closing times, coil current, fault current, velocity, position, motor and heater current, battery voltage, I2t sum
PD Hub channels3, expandable to 6 or 12
PD Hub sampling125 MS/s, 12 bit
PD Hub housingsteel, RAL 7035, IP 65
PD Hub dimensions600x600x221 mm (3 and 6 channels); 800x800x250 mm (12 channels)
PD Hub weightabout 35 kg; about 50 kg
PD Hub power50 W maximum; 220 VAC 50/60 Hz
PD Scope bandwidth16 kHz to 30 MHz, up to 1 GHz
Scope resolution10 bit
PD Scope record time1 μs to 20 μs
EDS MKII weightabout 2 kg
Central unit42U-19” rack
ProtocolsDNP3, MODBUS, OPC UA and TCP/IP, plus IEC 61850 and IEC 60870-5-104
Connectionfibre optic ST, Ethernet RJ45, coaxial RG223 or RG214
Operating temperature+5°C to +50°C; with options -20°C to +65°C
SensorsUHF horn and spiral antennas, internal UHF, HFCT, SF6 gas sensors

Request a price and lead time

GISNOVA SF6 monitoring system for HV GIS, covering partial discharge, SF6 gas and circuit breakers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can GISNOVA SF6 be installed on a GIS already in service?

Yes. The system is modular and suits both new and existing GIS, and its sensors are non-intrusive.

How many partial discharge channels does the PD Hub have?

The base unit has 3 channels, expandable to 6 or 12, with 125 MS/s sampling and 12 bit resolution.

Which protocols are supported for SCADA?

DNP3, MODBUS, OPC UA and TCP/IP, plus IEC 61850 and IEC 60870-5-104, over fibre optic or Ethernet RJ45.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides