Flowatch / Xtreme S / Totem multiphase flow meters for oil, gas and water in wells, up to 345 bar

Flowatch, Xtreme S and Totem multiphase flow meters and the WLR meter water-cut meter for wells with pressure up to 345 bar. They measure oil, water and gas flow rates in real time without prior phase separation, so they replace test separators onshore and offshore. Operating temperature up to 121 °C, explosion protection ATEX/IECEx.

Models
Flowatch 3i, Flowatch HS, Xtreme S (wet gas), Totem, WLR meter
Principle
Venturi restriction + velocity cross-correlation / velocity module; WLR microwave water-cut meter; HS: Cs-137 5 mCi gamma densitometer
Flowatch 3i
water cut 0–100 %, GVF 0–92 %; liquid uncertainty ±3–4 %, gas ±7 %; from 0.5″; non-radioactive
Flowatch HS
GVF 0–98 %; liquid ±3–5 %, gas ±4–5 %, water cut ±2–5 %; from 1.3″

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The Flowatch, Xtreme S and Totem multiphase flow meters and the WLR meter water-cut meter measure the oil, water and gas flow rates in well production in real time. Prior phase separation is not required. The instruments are installed on the wellhead equipment of onshore and offshore wells and on floating units for testing and monitoring, in place of bulky test separators. The technology platform is confirmed by more than 15 years of operating experience.

The measuring module is based on a Venturi tube. The mixture density is determined from the differential pressure, the flow velocity is found by cross-correlation of signals or by a separate velocity module, and the water cut by the WLR microwave water-cut meter. The Flowatch 3i is non-radioactive and is designed for basic well testing: water cut 0–100 %, gas volume fraction GVF 0–92 %, typical liquid uncertainty ±3 % up to 80 % GVF and ±4 % in the 80–92 % GVF range, gas uncertainty ±7 %. Sizes start from 0.5″, pressure loss is less than 1 bar. If needed it can be upgraded with a radioactive densitometer.

The Flowatch HS contains a gamma densitometer with a Cs-137 source of 5 mCi activity. It covers GVF up to 98 % with a liquid uncertainty of ±3–5 %, gas ±4–5 % and water cut ±2–5 %, sizes from 1.3″. The Xtreme S is a modular non-intrusive non-radioactive wet gas flow meter for conditions with a Lockhart–Martinelli parameter below 0.3. The ranges are GVF 90–100 % and WLR 0–100 %, the uncertainty is ±4 % for gas and ±10 % for liquid at a flow above 10 m³/h. Sizes are from 2″ to 14″, with ANSI/API flanged or hub connections. The body of UNS 31803 duplex steel, Inconel 625, SS316 or Inconel 825 complies with NACE MR0175/ISO 15156.

The design pressure of all models is up to 5000 psi (345 bar) and the temperature up to 121 °C. The electronics unit is built on a real-time controller running Linux. The interfaces are RS-485/RS-422 (single or redundant) and Ethernet, the protocols are Modbus and TCP/IP. Power supply is 24 V DC or 110–240 V AC, ingress protection is IP66, explosion protection is ATEX/IECEx Ex d or Ex ia IIB T3–T6. The equipment is certified to PED 2014/68/EU and is also supplied in a skid-mounted version.

Technical specifications

ModelsFlowatch 3i, Flowatch HS, Xtreme S (wet gas), Totem, WLR meter
PrincipleVenturi restriction + velocity cross-correlation / velocity module; WLR microwave water-cut meter; HS: Cs-137 5 mCi gamma densitometer
Flowatch 3iwater cut 0–100 %, GVF 0–92 %; liquid uncertainty ±3–4 %, gas ±7 %; from 0.5″; non-radioactive
Flowatch HSGVF 0–98 %; liquid ±3–5 %, gas ±4–5 %, water cut ±2–5 %; from 1.3″
Xtreme SGVF 90–100 %, WLR 0–100 % (Lockhart–Martinelli < 0.3); gas ±4 %, liquid ±10 % (>10 m³/h); 2″–14″
Design pressure and temperatureup to 5000 psi (345 bar), up to 121 °C
Pressure loss< 1 bar (Flowatch)
InterfacesRS-485/RS-422 (single or redundant), Ethernet; Modbus ASCII/RTU, TCP/IP
Power supply24 V DC or 110–240 V AC; 15–22 W
Explosion protectionATEX/IECEx Ex d (or Ex ia) IIB T3–T6
MaterialsAISI 316, Duplex UNS 31803, Inconel 625/825
StandardsPED 2014/68/EU, NACE MR0175/ISO 15156 (Xtreme S)

Request a price and lead time

Flowatch / Xtreme S / Totem multiphase flow meters for oil, gas and water in wells, up to 345 bar. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What pressure and temperature can the multiphase flow meters withstand?

The design pressure of all models is up to 5000 psi (345 bar) and the temperature up to 121 °C.

What gas volume fraction ranges do the Flowatch 3i, Flowatch HS and Xtreme S work in?

The Flowatch 3i covers GVF 0–92 %, the Flowatch HS up to 98 %, and the Xtreme S is designed for wet gas with GVF 90–100 %.

What explosion protection and ingress protection do the flow meters have?

Explosion protection ATEX/IECEx Ex d or Ex ia IIB T3–T6, ingress protection IP66. Power supply 24 V DC or 110–240 V AC.