EDS MKIII expert diagnostic system for main substation assets

EDS MKIII is an overall condition monitoring system for the main substation assets: current and voltage transformers, power transformers, circuit breakers, surge arresters and GIS switchgear. It brings real-time condition data from all these assets into one system for maintenance based on actual condition.

Monitored equipment
AIS/GIS breakers, CTs, VTs, power transformers, surge arresters, GIS, MV switchgear
Unit supply
110 V DC nominal, 93.5 to 121 V DC
Central unit consumption
about 50 W
Remote unit consumption
10 W or 5 W

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

EDS MKIII (Expert Diagnostic System) is used at distribution, transmission and generation sites to move from scheduled maintenance to maintenance based on actual condition. It monitors AIS and GIS circuit breakers, current and voltage transformers, power transformers (bushings, tap changers, tanks, cooling and dissolved gases), surge arresters, medium-voltage switchgear, batteries and other auxiliary equipment. Installation is non-intrusive, so it also suits substations already in service.

The system consists of a central unit, remote units for individual assets and monitoring software. The units are linked by a bidirectional fibre optic loop, and the high-voltage loop is normally kept separate from the medium-voltage loops. The central unit collects and processes the data and has a web server and an Ethernet switch. One of the remote units can be configured as the central unit when needed. The system can connect to an existing data collection system over IEC 60870-5-101, IEC 60870-5-104, Modbus or TCP/IP, or run stand-alone through a web application.

The AIS breaker unit monitors closing and opening times, auxiliary contact bounce, coil currents, operating mechanism time, coil continuity, battery voltage, SF6 density and temperature, and I2t during breaking. SF6 density ranges are 0 to 60 kg/m³, 15 to 45 kg/m³ or 30 to 60 kg/m³, with accuracy of ±2% of the measured value plus ±2% of the full range. The surge arrester unit measures discharge current and third harmonic. The medium-voltage unit serves up to 10 breakers, and the voltage transformer unit has 8 or 16 digital inputs, 3 analogue inputs and a 10 kHz sample rate.

For power transformers, the system offers basic and advanced configurations, covering hotspot temperature, ageing rate, loss of life, moisture content in cellulose, cooling efficiency, tap changer position and counting, and overload capacity to IEC 60076-7.

The central and remote units run from a 110 V DC supply with a range of 93.5 to 121 V. The central unit draws about 50 W, the remote units 10 W or 5 W, and each unit weighs about 2 kg. Indoor units come as a 3U module for a 14 or 19 inch rack with IP 20 protection. Outdoor units sit in a 400 x 500 x 350 mm galvanised steel cabinet with IP 54, work between -40 °C and +85 °C, and tolerate 5 to 95% relative humidity at altitudes up to 2000 m. Self-diagnostics check the system continuously and raise an alert on any fault. Optical connections use ST connectors on 62.5/125 micron multimode fibre.

Technical specifications

Monitored equipmentAIS/GIS breakers, CTs, VTs, power transformers, surge arresters, GIS, MV switchgear
Unit supply110 V DC nominal, 93.5 to 121 V DC
Central unit consumptionabout 50 W
Remote unit consumption10 W or 5 W
Supply protectionfuse 1 A (central), 0.1 A or 0.2 A (remote)
Unit weightabout 2 kg
Indoor version3U module for 14 or 19 inch rack, IP 20
Outdoor versiongalvanised steel cabinet, 400 x 500 x 350 mm
Outdoor operating temperature-40 °C to +85 °C
Relative humidity5–95%
Installation altitudeup to 2000 m
CommunicationEthernet, TCP/IP, IEC 60870-5-101, IEC 60870-5-104, Modbus
Optical connectorST, multimode 62.5 / 125 micron
SF6 density range0–60, 15–45 or 30–60 kg/m³
SF6 density accuracy±2% of reading, ±2% of full range
VT unit8 or 16 digital inputs, 3 analogue inputs, 10 kHz sampling
MV switchgear unitup to 10 breakers
StandardsIEC 60076-7, IEC 60354, IEC 60099-5, EN 61326-1, IEC EN 61010-1

Request a price and lead time

EDS MKIII expert diagnostic system for main substation assets. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can the system be installed in a substation that is in service?

Yes. Installation is non-intrusive, and the mix of units is chosen to suit the layout of each substation.

Which protocols does the system use to send data?

The central unit has Ethernet with TCP/IP and supports IEC 60870-5-101, IEC 60870-5-104 and Modbus.

How many breakers can one medium-voltage monitoring unit cover?

The medium-voltage switchgear monitoring unit serves up to 10 breakers.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides