International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

CPC-03 — digital gas pressure transducer, intrinsically safe, RS-GAZ2

A digital transducer of gauge or absolute gas pressure in an acid-resistant steel case. The intrinsically safe version II 2G Ex ia IIB T4 Gb allows operation in hazardous zones 1 and 2. It is used at gas regulator and gas distribution stations and together with correctors and recorders.

Measurement
gauge or absolute gas pressure
Gauge ranges
0–10, 0–17, 0–100, 0–600, 0–1600, 400–1600, 1400–6300 kPa
Absolute ranges
50–300, 90–600, 250–1700, 600–4000, 1000–7000 kPa
Accuracy
for example ±0.2% of the measured value (23 °C), ±0.4% over the whole temperature range

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The CPC-03 measures gauge or absolute gas pressure, and the whole device is made of acid-resistant steel. Measurement, data processing and transmission are performed by a low-power microcontroller. A high-class sensor with microprocessor correction of the characteristic gives high accuracy over the whole operating temperature range and long-term stability. The stated error is specified over the whole ambient temperature range.

The device has the intrinsically safe version II 2G Ex ia IIB T4 Gb (certificate KDB 11ATEX145) and works in hazardous zones 1 and 2. Setup and reading go through an interface compatible with RS-GAZ2. This is a four-wire connection combining power supply and RS-485, with the Gaz-Modem 2/3 protocol (others possible), at a speed from 9600 to 115 200 bit/s. Current consumption is low, 2–4 mA at a supply voltage of 2.7–7.5 V, so the transducer is suitable for battery-powered devices. The CPC-03 works with the CMK-02 and CMK-03 volume correctors, the CRP-03 recorder or as a stand-alone device.

For gauge pressure, ranges of 0–10, 0–17, 0–100, 0–600 and 0–1600 kPa are made, as well as 400–1600 and 1400–6300 kPa, and for absolute pressure 50–300, 90–600, 250–1700, 600–4000 and 1000–7000 kPa. For the upper ranges the error is ±0.2% of the measured value at 23 ± 3 °C and ±0.4% over the whole temperature range. The permissible overload, for example for the 6300 kPa range, is 9000 kPa.

The fitting and case are made of acid-resistant steel 1H18N9T, the sensor diaphragm of 316L steel, and the other parts in contact with the medium of 1.4122 steel and Viton. The process connection is a gauge M20×1.5, others on request. The degree of protection depends on the electrical connector: type H — IP65, type E — IP66/67. The length is about 161 mm, the diameter 38 mm, the weight 0.55 kg, and the operating temperature is from −25 to +55 °C. Reverse polarity and overvoltage protection are built in (90 V arrester, 10 V suppressors). Typical installation sites are process pressure control at gas regulator and gas distribution stations, additional measurement points for correctors and recorders, and gas network telemetry.

Technical specifications

Measurementgauge or absolute gas pressure
Gauge ranges0–10, 0–17, 0–100, 0–600, 0–1600, 400–1600, 1400–6300 kPa
Absolute ranges50–300, 90–600, 250–1700, 600–4000, 1000–7000 kPa
Accuracyfor example ±0.2% of the measured value (23 °C), ±0.4% over the whole temperature range
Materialsacid-resistant steel 1H18N9T, diaphragm 316L, Viton
ConnectionM20×1.5 gauge, others on request
InterfaceRS-GAZ2 (power + RS-485), Gaz-Modem 2/3, 9600–115 200 bit/s
Power supply2.7–7.5 V DC, 2–4 mA
Explosion protectionII 2G Ex ia IIB T4 Gb (KDB 11ATEX145)
ProtectionIP65 (type H), IP66/67 (type E)
Dimensions, weightØ38 × approx. 161 mm, 0.55 kg
Temperature−25…+55 °C

Request a price and lead time

CPC-03 — digital gas pressure transducer, intrinsically safe, RS-GAZ2. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which pressure ranges does the CPC-03 have?

Gauge pressure from 0–10 to 1400–6300 kPa, absolute pressure from 50–300 to 1000–7000 kPa. The full list of ranges is given in the specifications.

What explosion protection version does the CPC-03 have?

The intrinsically safe version II 2G Ex ia IIB T4 Gb, certificate KDB 11ATEX145. The device works in hazardous zones 1 and 2.

Is the CPC-03 suitable for battery-powered devices?

Yes, consumption is 2–4 mA at a supply voltage of 2.7–7.5 V. The transducer works with the CMK-02 and CMK-03 correctors and the CRP-03 recorder or as a stand-alone device.

Similar equipment from other manufacturers