CGS capacitive sensor for hydro generator air gaps, 3–50 mm range
The CGS capacitive gap sensors measure the distance between rotor and stator in hydro generators, so that eccentricity or out-of-roundness can be caught in time, since both reduce efficiency and lead to damage. Three probe sizes, CGP-02, CGP-03 and CGP-04, together cover the range from 3 to 50 mm.
- Probe types
- CGP-02, CGP-03, CGP-04
- Measuring range
- 3–15 mm / 5–25 mm / 10–50 mm
- Recommended gap
- 5–12 mm / 12–22 mm / 22–47 mm
- Error over full range
- ±3 % / ±3 % / ±5 %
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The CGL linearisation module converts the probe signal into a 4-20 mA or 2-10 V output proportional to the gap, for use in continuous monitoring systems. The probe-to-module cable can run to 10 m, the frequency response is 0–1000 Hz (−3 dB), and temperature drift is below 300 ppm/°C. The module takes +24 V DC ±10 % at up to 220 mA, measures 175 x 80 x 60 mm with an end plate, and has an IP66 enclosure. It operates from −15 to +70 °C at up to 95 % humidity, non-condensing, while the probe itself operates from −15 to +125 °C. The kit comes with the probes, linearisation modules, junction box and mounting materials, including epoxy.
The probes come in three types. The CGP-02, measuring 135 × 32 × 1.7 mm, covers 3–15 mm with a recommended gap of 5–12 mm and a ±3 % error, and can sit up to 0.5 m from the top of the core. The CGP-03, measuring 230 × 32 × 2.4 mm, covers 5–25 mm with a recommended gap of 12–22 mm and a ±3 % error. The CGP-04, measuring 250 × 40 × 3.2 mm, covers 10–50 mm with a recommended gap of 22–47 mm and a ±5 % error. For the CGP-03 and CGP-04 the distance from the top of the core can be up to 1 m.
Each probe is made from a printed circuit board and bonded into the bore of the stator core with a special epoxy resin. Its output is directly proportional to the gap, so it reproduces the pole profile. The probe has a low profile and high temperature stability, and is unaffected by magnetic fields, dust, oil, and electromagnetic and radio frequency interference. No separate calibration is required.
The air gap is the distance between the outer diameter of the rotor and the inner diameter of the stator. In a hydro generator both parts are fairly flexible, and their shape and position change under centrifugal force, heating, magnetic forces and mechanical damage. In an ageing machine, stator deformation can shrink the gap to a critical value and force an unplanned shutdown. Offset from centre and out-of-roundness also cause local heating from the magnetic field, or rubbing of the rotor against the stator. Continuous gap monitoring shows how the generator is changing and gives time to fix the problem before it fails in service.
Technical specifications
| Probe types | CGP-02, CGP-03, CGP-04 |
|---|---|
| Measuring range | 3–15 mm / 5–25 mm / 10–50 mm |
| Recommended gap | 5–12 mm / 12–22 mm / 22–47 mm |
| Error over full range | ±3 % / ±3 % / ±5 % |
| Probe dimensions | 135 × 32 × 1.7 mm / 230 × 32 × 2.4 mm / 250 × 40 × 3.2 mm |
| Maximum distance from top of core | 0.5 m / 1 m / 1 m |
| Probe to module cable | 10 m |
| Probe operating temperature | −15…125 °C |
| Temperature drift | <300 ppm/°C |
| Frequency response | 0–1000 Hz (−3 dB) |
| Module output | 4-20 mA or 2-10 V |
| Module power | +24 V DC ±10 %, up to 220 mA |
| Module operating temperature | −15…70 °C |
| Relative humidity | 95 % non-condensing |
| Module dimensions | 175 x 80 x 60 mm |
| Module protection rating | IP66 |
Part numbers
Show all part numbers (6)
CGS020210, CGS020310, CGS020410, CGP-02, CGP-03, CGP-04
Request a price and lead time
CGS capacitive sensor for hydro generator air gaps, 3–50 mm range. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which probe should be used for a 15 mm gap?
The CGP-03. Its recommended gap is 12–22 mm, with a measuring range of 5–25 mm and a ±3 % error.
What output does the monitoring system receive?
The CGL linearisation module provides 4-20 mA or 2-10 V, proportional to the measured gap.
How is the probe fitted in the generator?
The printed circuit board probe is bonded into the bore of the stator core with the epoxy resin supplied in the kit.