408/408XT fibre optic winding hot-spot temperature monitor, 4 to 16 channels
The 408/408XT is a multichannel fibre optic system that measures hot-spot winding temperature in dry and oil-filled transformers in real time. Paired with T2 optical sensors, it reads temperature directly in the winding, faster and more accurately than top-oil thermocouples.
- Type
- Multichannel fibre optic winding temperature monitor
- Number of channels
- 4, 6, 8, 10, 12, 14 or 16
- Measuring range
- -50 °C to 200 °C
- Resolution
- 0.1 °C
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The system serves on-site monitoring of oil-filled power transformers and tap changers, as well as dry-type transformers. Its data supports transformer heat-run tests, controls cooling according to the actual hot-spot temperature, and allows dynamic loading without shortening equipment life. Direct measurement complements indirect calculations made with thermal models.
Each optical channel reports a reading every 250 ms, so peaks and emergency overloads are detected almost at once. The GaAs semiconductor sensor shows no drift over time, and the system needs no recalibration over its service life. The sensor is built only from dielectric materials and withstands kerosene drying, factory heat tests, long immersion in oil, thermal cycling and vibration.
The system takes 4, 6, 8, 10, 12, 14 or 16 optical channels. The measuring range runs from -50 °C to 200 °C with 0.1 °C resolution. Accuracy is ±1.0 °C from -20 °C to 150 °C and ±2.5 °C outside that band. Each channel has a four-digit LED display, and on channels 9 to 16 the display is multiplexed. Built-in memory is 2 GB, optionally 4 GB, with time stamps from a real-time clock. With 8 channels logged every minute, the memory lasts more than thirty years.
The system has 8 Form-C (SPDT) relays rated 8 A at 240 V AC, 0.2 A at 125 V DC or 8 A at 24 V DC at 50 °C. They drive cooling control, cabinet heating, alarms and tripping, and a ninth relay signals a system fault. Up to 16 analogue outputs of 4-20 mA are available, one per channel. Interfaces are isolated RS-485 and Ethernet 10/100BASE-T, optionally 100BASE-FX. Protocols are ASCII, Modbus RTU, HTTP and Modbus over Ethernet, with optional DNP 3.0, IEC 60870-5-101, IEC 60870-5-104 and IEC 61850. The 408XT version gives access to data through a web browser.
Power supply is 95–240 V AC at 50/60 Hz or 135–240 V DC, with consumption of 18 W when all relays are energised. Dimensions are 280 x 110 x 70 mm for 1 to 8 channels, or 95 mm deep for 9 to 16 channels, and the weight is 2.5 kg. The unit mounts on the cabinet door with 4 x M8 fixings at the front, or on the back panel with 4 x M6 fixings, at 255 mm x 85 mm hole spacing. Operating temperature runs from -40 °C to +72 °C at 5–90% humidity, non-condensing. Compliance is verified against IEEE C37.90, IEEE C37.90.1-2002, the IEC 61000-4 series and IEC 61180.
Technical specifications
| Type | Multichannel fibre optic winding temperature monitor |
|---|---|
| Number of channels | 4, 6, 8, 10, 12, 14 or 16 |
| Measuring range | -50 °C to 200 °C |
| Resolution | 0.1 °C |
| Accuracy | ±1.0 °C from -20 °C to 150 °C; ±2.5 °C outside this range |
| Reading interval | 250 ms per channel |
| Memory | 2 GB, optionally 4 GB |
| Relays | 8 Form-C (SPDT) and a 9th relay for system fault |
| Relay ratings | 8 A / 240 V AC, 0.2 A / 125 V DC, 8 A / 24 V DC at 50 °C |
| Analogue outputs | 4-20 mA, up to 16 |
| Interfaces | RS-485, Ethernet 10/100BASE-T, optionally 100BASE-FX |
| Protocols | ASCII, Modbus, HTTP, optionally DNP 3.0, IEC 60870-5-101/104, IEC 61850 |
| Optical connectors | ST |
| Power supply | 95–240 V AC, 50/60 Hz or 135–240 V DC |
| Consumption | 18 W with all relays |
| Dimensions | 280 x 110 x 70 mm (1–8 channels), 95 mm deep (9–16 channels) |
| Weight | 2.5 kg |
| Operating temperature | -40 °C to +72 °C, 5–90% non-condensing |
Part numbers
Show all part numbers (10)
408-08-SP1-M2, 408-14-SP1-M4, 408XT-04-SP0-EP0-M2-FX, 408XT-08-SP0-EP0-M4, 408XT-10-SP1-EP1-M2, 408XT-16-SP1-EP0-M4-FX, 408LC-04-EP1-FX, 408LC-16-EP0-SF, 408DC-04-SP0-EP0-M2, 408-COM-4-NMA
Request a price and lead time
408/408XT fibre optic winding hot-spot temperature monitor, 4 to 16 channels. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many channels can the system have?
4, 6, 8, 10, 12, 14 or 16 optical channels, with one sensor per channel.
Can the system control transformer cooling on its own?
Yes, 8 built-in Form-C relays control cooling, cabinet heating, alarms and tripping using the built-in calculation algorithms.
How does the system connect to substation SCADA?
Through RS-485 or Ethernet, using Modbus, with optional DNP 3.0, IEC 60870-5-101/104 or IEC 61850.