351 Pressure and Vacuum Bleeder for Sealed Transformer Tanks, 3 to 12 PSIG

The 351 series valve equalises pressure in a sealed transformer tank, venting gas when pressure is excessive and admitting air when a vacuum forms. Set points adjust from 3 to 12 PSIG and -3 to -12 PSIG, with repeatability of ±0.5 PSI.

Type
pressure relief and air admission valve
Pressure range
3–12 PSIG (0.21–0.83 bar)
Vacuum range
-3 to -12 PSIG (-0.21 to -0.83 bar)
Repeatability
±0.5 PSI

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The 351 bleeder is fitted to the gas space of transformers that use a nitrogen cushion, to conservator tanks with an air space, to on-load tap changers and to other sealed electrical tanks where pressure has to stay within set limits. When the internal pressure reaches the set point, the valve releases gas from the tank to atmosphere. If a vacuum forms and the tank pressure falls too far, the valve admits air and limits how deep the vacuum can go.

The body is made from two end caps around a central section that holds the valve ports and connecting passages. The ports open a path between the tank and atmosphere only when pressure is excessive or a vacuum exists. Each outer chamber is separated from the body by a flexible silicone or Viton diaphragm, and each diaphragm is spring loaded. Above the set pressure, force on diaphragm A overcomes its spring and lifts seat 1, letting gas escape. Under vacuum, diaphragm B opens seat 2 and air flows into the tank. Valve seats and sealing rings carry a PTFE coating.

Adjustment ranges are 3 to 12 PSIG (0.21 to 0.83 bar) for pressure and -3 to -12 PSIG (-0.21 to -0.83 bar) for vacuum, with repeatability of ±0.5 PSI at both set points. The valves meet ANSI standards for transformer equipment. They handle gas or air as the medium, with an ambient temperature range of -40 to 70 °C.

Standard versions mount on the top, side or bottom of the vessel, with 1/4″-18 NPT or 1/8″-27 NPT connections in external or internal thread. A pressure gauge for local readout and an integral sampling valve for gas analysis can be added. Openings are screened against contamination. The housing suits indoor and outdoor sites, and the standard finish is ANSI #70 thermosetting powder paint, with C5-High coating available to order. Set points are checked from an adjustable air supply. Air goes to the 1/4″ NPT nipple on the pressure side, with flexible tubing attached to the 5/16″ port, and the arrangement is reversed for the vacuum side. The opening moment is read from bubbles in a tube submerged in water.

Technical specifications

Typepressure relief and air admission valve
Pressure range3–12 PSIG (0.21–0.83 bar)
Vacuum range-3 to -12 PSIG (-0.21 to -0.83 bar)
Repeatability±0.5 PSI
Mountingtop, side or bottom
Connection1/4″-18 NPT; 1/8″-27 NPT, external or internal thread
Diaphragmsilicone / Viton
Mediumgas / air
Finishpowder paint ANSI #70 (standard); C5-High (option)
Ambient temperature-40 to 70 °C
Optionspressure gauge, sampling valve

Part numbers

Show all part numbers (10)

351-003-01, 351-005-02, 351-007-01, 351-009-02, 351-010-02, 351-010-03, 351-2K, 351-2-2, 351-2-63, 351-2-134B

Request a price and lead time

351 Pressure and Vacuum Bleeder for Sealed Transformer Tanks, 3 to 12 PSIG. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Where is the 351 valve fitted?

On the gas space of transformers with a nitrogen cushion, on conservator tanks with an air space, on on-load tap changers and on other sealed electrical tanks.

How accurate is the set point?

Repeatability is ±0.5 PSI at both the pressure set point (3 to 12 PSIG) and the vacuum set point (-3 to -12 PSIG).

Can gas be sampled through the valve?

Yes. On request the valve can include an integral sampling valve and a pressure gauge for local readout.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides