SDPD / SRP / PD 3000 — cryogenic piston pumps for filling cylinders with industrial and medical gases, up to 420 bar

PPC, SDPD, SRP and PD 3000 are cryogenic piston pumps for stations that fill cylinders and buffer vessels with compressed industrial and medical gases. The highest design pressure of 420 bar is offered by the SDPD 22/20, and the capacity of the PD 3000 reaches 15.6 l/min.

PPC 35/26, 45/26
LCO₂, LN₂O; design pressure 120 / 100 bar; no insulation, grease lubrication; up to ≈18 l/min
SDPD 22/20, 30/20, 30/32
LOX, LIN, LAr, LCO₂, LN₂O, LNG; 420 bar (22/20), 280 bar (30/20, 30/32); vacuum-insulated cold end; 0.7–10 l/min
SRP
up to 380 bar, oil crank drive, vacuum insulation, long-life seals; filling cylinders of 200 and 300 bar, incl. medical LOX
PD 3000 (vertical)
LO₂, LN₂, LAr, LCO₂, LN₂O, LNG, LH₂; 6000 psi (≈413 bar), 9000 psi on request; models 303 and 413 bar; up to 15.6 l/min; twin and triple units

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The pump takes cryogenic liquid from the tank and raises its pressure to filling pressure, after which the liquid is gasified in a high-pressure vaporizer and goes to the ramps. The more powerful MRP, LDPD and HPP pumps are listed in the catalog as a separate item.

The PPC pump is horizontal, with grease lubrication of the crank drive, without cold-end insulation, for liquid CO₂ and N₂O. The PPC 35/26 is rated for 120 bar and the PPC 45/26 for 100 bar, with capacity up to ≈18 l/min. It has a stainless steel piston and a conical seal designed for elevated suction pressure, and a gas control unit is available on request. It is used for filling cylinders with liquid carbon dioxide and nitrous oxide, in a basic or extended version with a bypass on the frame.

The SDPD pump is horizontal, with a vacuum-insulated cold end, for LOX, LIN, LAr, LCO₂, LN₂O and LNG. The SDPD 22/20 is rated for 420 bar, the SDPD 30/20 and 30/32 for 280 bar, with capacity of 0.7–10 l/min; typical use is cylinders of 150 and 200 bar. The cold end is inclined at 10° for degassing, the suction chamber separates vapor from liquid, hat-type seals remain elastic at low temperatures, and the piston is bronze. Vacuum insulation keeps the pump cold, so it restarts without venting.

The SRP pump is horizontal, with an oil crank drive, vacuum insulation and long-life seals, pressure up to 380 bar. It fills cylinders of 200 and 300 bar, including with medical oxygen, in intermittent and continuous duty. The PD 3000 (CVI) is vertical, grease-lubricated, for LO₂, LN₂, LAr, LCO₂, LN₂O, LNG and LH₂. Design pressure is 6000 psi, 9000 psi on request, with models for 303 and 413 bar and capacity up to 15.6 l/min; twin and triple units are available. The PD 3000 does not carry the CE mark and, according to the manufacturer, is not intended for the European market.

SDPD options: PT100 sensors for cool-down, cavitation and leak protection, seal heating for cold standby of more than 3 h, and suction from a thermosiphon vessel. All pumps are designed to IGC 11/82 recommendations and are tested mechanically and cryogenically.

Technical specifications

PPC 35/26, 45/26LCO₂, LN₂O; design pressure 120 / 100 bar; no insulation, grease lubrication; up to ≈18 l/min
SDPD 22/20, 30/20, 30/32LOX, LIN, LAr, LCO₂, LN₂O, LNG; 420 bar (22/20), 280 bar (30/20, 30/32); vacuum-insulated cold end; 0.7–10 l/min
SRPup to 380 bar, oil crank drive, vacuum insulation, long-life seals; filling cylinders of 200 and 300 bar, incl. medical LOX
PD 3000 (vertical)LO₂, LN₂, LAr, LCO₂, LN₂O, LNG, LH₂; 6000 psi (≈413 bar), 9000 psi on request; models 303 and 413 bar; up to 15.6 l/min; twin and triple units
SDPD designcold end inclined at 10° for degassing, vapor separator in the suction chamber, hat-type seals, bronze piston, in-line suction valve
OptionsPT100 sensors (cool-down, cavitation, leak), seal heating, suction from a thermosiphon vessel
StandardsIGC 11/82 recommendations; mechanical and cryogenic tests of every pump

Request a price and lead time

SDPD / SRP / PD 3000 — cryogenic piston pumps for filling cylinders with industrial and medical gases, up to 420 bar. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What maximum pressure are these pumps rated for?

The SDPD 22/20 is rated for 420 bar, and the SRP operates up to 380 bar. The PD 3000 has a design pressure of 6000 psi, 9000 psi on request, and models are produced for 303 and 413 bar.

What media does the SDPD pump?

LOX, LIN, LAr, LCO₂, LN₂O and LNG at a capacity of 0.7–10 l/min. It is typically used to fill cylinders of 150 and 200 bar.

Which pump is intended for liquid carbon dioxide and nitrous oxide?

The PPC pump is intended for LCO₂ and LN₂O. The PPC 35/26 is rated for 120 bar and the PPC 45/26 for 100 bar, with capacity up to ≈18 l/min.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides