TIY programmable isolated thermocouple transmitter, 4-20mA, 12-42DC, push button calibration

The TIY converts a thermocouple or millivolt input into 4-20mA, linear with temperature. Quick Ranging push buttons, an integral indicator, 2-wire 12-42DC power and 500Vrms isolation.

Type
Programmable isolated thermocouple transmitter
Input
ISA thermocouples (J, K, E, T, R, S, N) and others, mV
Temperature range
-190°C to +1820°C, no minimum span
Output
4-20mA, linear with temperature or millivolt input

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TIY is a digital/analogue hybrid: a microprocessor-based, 2-wire, programmable isolated transmitter. It accepts a non-linear temperature input from standard ISA thermocouples (types J, K, E, T, R, S and N) and other types, as well as from millivolt sources. The 4-20mA output is linear with temperature or with the millivolt input.

Setup is made in the field with tactile push buttons and quick-change solderless jumpers, so no hand-held configurator is needed. Thermocouple type, range, upscale or downscale drive and linearisation are selected there. Zero and span are set by Quick Ranging while reading the integral indicator, with no calibrator. The temperature range is -190°C to +1820°C with no minimum span, and automatic digital reference junction compensation maintains long-term accuracy.

The indicator reads the input in °C, °F or mV, shows zero and span adjustments, and keeps showing the process temperature even when the output goes overrange or underrange. Self-diagnostics sense sensor failure and errors in calibration, memory and unit function, and indicate them on the display.

Output accuracy is ±0.05% of span, ripple is below 10mVp-p up to 120Hz across a 250 ohm load and common mode rejection is at least 120dB at 50Hz/60Hz. 500Vrms galvanic isolation between input and output prevents false signals from ground loops. The unit withstands ±42V on the input and ±60V on the output without damage, and output current limiting is 125% of span typical and 130% of span maximum.

The housing is a hockey puck type with a DIN rail clip. For field mounting the unit can be ordered in an explosion-proof enclosure, and the DIN-style housing suits high-density cabinet installation. The rating is Non-Incendive/Div. 2, Zone 2. The unit is not for use in SIS and is RoHS compliant.

Technical specifications

TypeProgrammable isolated thermocouple transmitter
InputISA thermocouples (J, K, E, T, R, S, N) and others, mV
Temperature range-190°C to +1820°C, no minimum span
Output4-20mA, linear with temperature or millivolt input
Power12-42DC, 2-wire, loop powered
Output accuracy±0.05% of span
Isolation500Vrms galvanic isolation between input and output
Common mode rejectionAt least 120dB at 50Hz/60Hz
RippleLess than 10mVp-p (up to 120Hz) across a 250 ohm load
Output current limiting125% of span typical, 130% of span maximum
Operating limitsNo damage up to ±42V on input and ±60V on output
Burnout protectionUpscale (standard), downscale by solderless jumper
HousingHockey puck housing with DIN rail clip
Integral displayYes
ConfigurationPush buttons, solderless jumpers
Hazardous area certificationsNon-Incendive/Div. 2, Zone 2

Part numbers

Show all part numbers (1)

TIY/PRG/4-20mA/12-42DC [DN]

How it compares with similar models

ParameterTIY programmable isolated thermocouple transmitter, 4-20mA, 12-42DC, push button calibrationRIY programmable isolated RTD transmitter, 4-20mA, 12-42DC, push button setup, displayTDZ3 dual input HART temperature transmitter, 4-20mA, 12-42DC loop poweredSTZ functional safety dual input HART temperature transmitter, SIL 2/3, 4-20mA, 12-42DC
TypeProgrammable isolated thermocouple transmitterProgrammable isolated RTD transmitterDual input smart HART temperature transmitterFunctional safety dual input smart HART temperature transmitter
InputISA thermocouples (J, K, E, T, R, S, N) and others, mV2-, 3- or 4-wire RTD or resistance sourceDual sensor, programmable: RTD, T/C, mV, ohms, potentiometerOne or two sensors: RTD (14 types), T/C (9 types), mV, ohms, potentiometer
Output4-20mA, linear with temperature or millivolt input4-20mA, linear with temperature or ohm input, direct or reverse4-20mA with HART4-20mA with HART (HART 7)
Isolation500Vrms galvanic isolation between input and outputFully isolatedFully isolatedFully isolated
Integral displayYesYes, 4-digit LCDYesYes
ConfigurationPush buttons, solderless jumpersPush buttons, switchesPC, USB cable, HARTPC, USB cable, HART

Request a price and lead time

TIY programmable isolated thermocouple transmitter, 4-20mA, 12-42DC, push button calibration. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which inputs does the TIY accept?

ISA thermocouples (types J, K, E, T, R, S and N) and other types, plus millivolt sources, over -190°C to +1820°C with no minimum span.

How is the TIY calibrated?

Zero and span are set with the push buttons by Quick Ranging, reading the integral indicator, with no calibrator.

How much isolation is there between input and output?

500Vrms galvanic isolation, which prevents false signals due to ground loops.