The SCT converts a current or voltage input into an isolated current or voltage output in a different range. The DSCT puts two independent, isolated SCT circuits on one plug-in card, so 22 channels fit in a 19" relay rack.

Type
signal converter, single channel (SCT) and dual channel (DSCT)
Input signal
current or voltage
Output signal
current or voltage, isolated
Typical conversion
0-10V to 4-20mA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A current or voltage signal goes in and an isolated current or voltage signal in a different range comes out. A typical conversion takes a 0-10V input to a 4-20mA output. The SCT works with most standard and many non-standard current and voltage signals. A common use is as the interface module between a digital multiplexer and existing analogue control loops that are being modernised.

The DSCT is a pair of independent, isolated SCT circuits on a single plug-in card. For high-density installations, 22 channels can be mounted in a 19" relay rack.

The standard housing is a corrosion-resistant aluminium case with CSA approval and a "U-Back" mounting bracket, sized for a 3" by 7-1/2" installation space. Other housings are a plug-in card for rack mounting and a panel-mount housing for flush mounting. Enclosures offered for the SCT are explosion-proof, watertight and transparent-cover versions, each meeting NEMA specifications.

Input, output and power supply terminals are completely isolated from one another, which keeps noise and other signal errors down. Output ripple is low, 10 mV peak to peak, so the unit suits interfacing with computer-based systems. The -RF option adds a patented filter assembly that stops radio frequency interference entering the unit; in a DSCT the same protection comes from fitting the -RF option in a 19" rack. With the -SC option, the input and output current ranges can be selected in the field.

Input resistance is low for current signals and above 10 megohms for voltage signals, so the SCT can be placed in an existing system without loss of performance. The unit is a 4-wire design.

Technical specifications

Typesignal converter, single channel (SCT) and dual channel (DSCT)
Input signalcurrent or voltage
Output signalcurrent or voltage, isolated
Typical conversion0-10V to 4-20mA
Isolationcomplete: input, output and power supply
Output ripple10 mV P/P
Input resistance, voltage signalover 10 megohms
Channels in a 19" rack (DSCT)22
Housingcorrosion-resistant aluminium, "U-Back" bracket, 3" by 7-1/2" space
Options-RF (radio frequency interference protection), -SC (field-selectable current ranges)

How it compares with similar models

ParameterSCT/DSCT Signal Converter, Single and Dual Channel, 4-WireSIX 1-5V/4-20mA 2-Wire Signal Isolator and Converter, 1500 Vrms IsolationMIT 2XPRG 2-Channel 4-Wire Signal Isolator and Converter, 20-125 VDC or 90-250 VAC SupplyFCT [UB] 4-Wire Signal Converter and Isolator with Universal Power Input, Surface-Mount Housing
Typesignal converter, single channel (SCT) and dual channel (DSCT)Signal isolator, converter and repeater, 2-wireMulti-channel signal isolator and converter, 4-wireSignal converter and isolator, 4-wire
Isolationcomplete: input, output and power supply1500 Vrms input to output; 500 Vrms with -RF optionUp to 1000 Vrms input to output and channel to channel; 2500 Vrms between power and signals1000 Vrms between input, output and power
Housingcorrosion-resistant aluminium, "U-Back" bracket, 3" by 7-1/2" spaceDIN-style housing, 32 mm G-type (EN50035) and 35 mm Top Hat (EN50022) railUniversal DIN-style housing, 32 mm G-type and 35 mm Top Hat railUB with U-back bracket for surface mounting

Request a price and lead time

SCT/DSCT Signal Converter, Single and Dual Channel, 4-Wire. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which signals does the SCT accept and output?

Input and output can each be current or voltage in different ranges, for example 0-10V in and 4-20mA out. The output is isolated.

How many channels fit in a 19" rack?

A 19" relay rack takes 22 channels on DSCT cards, each card carrying two independent, isolated converters.

Are the input, output and power supply isolated?

Yes, all three are completely isolated from each other, and output ripple is 10 mV peak to peak.