RBT 4-wire RTD transmitter, ±0.1% accuracy

The RBT accepts any standard 2-, 3- or 4-wire RTD in platinum, copper or nickel and gives a proportional current output. Accuracy is ±0.1% of span, with input, output and power fully isolated. Linearisation and RFI options are available.

Type
4-wire RTD transmitter
Input
standard 2-, 3- or 4-wire RTD (platinum, copper, nickel)
Output
proportional current
Accuracy
±0.1% of span

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

A 4-wire transmitter for resistance temperature detectors, the RBT takes input from any standard 2-, 3- or 4-wire RTD made of platinum, copper or nickel. It converts that input into a proportional current output for a readout device or another process instrument.

Accuracy is ±0.1% of span. A chopper-stabilised amplifier keeps performance up even at low spans. The unit also has high input impedance, low sensor excitation, high stability and immunity to short circuits.

Input, output and power are completely isolated from each other. This removes signal errors caused by ground loops, motor noise and other electrical interference, and the high common-mode rejection keeps long input lead runs from degrading the signal.

The options include -LNP and -LNN, which remove the non-linearity of platinum or nickel RTDs, -RO (reversed input/output current relationship) for thermistor inputs, and -RF for resistance to radio-frequency and electromagnetic interference.

Housings are surface-mount and high-density plug-in card. Certifications are CSA General Location; Explosion-proof, Division I, Groups C and D (in EX enclosure); and City of Los Angeles General Location.

Technical specifications

Type4-wire RTD transmitter
Inputstandard 2-, 3- or 4-wire RTD (platinum, copper, nickel)
Outputproportional current
Accuracy±0.1% of span
Amplifierchopper-stabilised
Isolationcomplete, input/output/power
Options-LNP, -LNN, -RO, -RF
Housingssurface-mount; high-density plug-in card
CertificationCSA General Location; Explosion-proof, Division I, Groups C and D (EX enclosure); City of Los Angeles General Location

How it compares with similar models

ParameterRBT 4-wire RTD transmitter, ±0.1% accuracyECT 4-20mA/4-20mA/5.5VLP 2-Wire Input-Loop-Powered Signal Isolator and ConverterLIT 4-Wire Linear Integrating Totaliser, Pulse Output Proportional to the Input SignalMVT 4-Wire Millivolt Transmitter with Full Input, Output and Power Isolation
Type4-wire RTD transmitterSignal isolator and converter, 2-wireLinear integrating totaliser, 4-wireMillivolt transmitter, 4-wire
Inputstandard 2-, 3- or 4-wire RTD (platinum, copper, nickel)4-20 mA, fixedStandard current or voltage process signalGrounded or ungrounded millivolt signal
Outputproportional current4-20 mA, fixedPulse string proportional to the inputCurrent or voltage in a range of spans
Isolationcomplete, input/output/power500 Vrms for input-loop-powered versionsPower from input-output; input-output with relay outputInput, output and power isolated
Housingssurface-mount; high-density plug-in card—Aluminium U-Back 3 x 7-1/2 inch; plug-in; panel mount; EurocardSurface mount; plug-in card; EX

Request a price and lead time

RBT 4-wire RTD transmitter, ±0.1% accuracy. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which sensors can be connected to the RBT?

Any standard 2-, 3- or 4-wire RTD made of platinum, copper or nickel.

What is the difference between -LNP/-LNN and -RO?

-LNP and -LNN remove the non-linearity of platinum or nickel RTDs, while -RO reverses the input/output current relationship and is used for thermistor inputs.

How is the unit protected against electrical interference?

Input, output and power are fully isolated, and high common-mode rejection limits the effect of interference on long lead runs.