LIT 4-Wire Linear Integrating Totaliser, Pulse Output Proportional to the Input Signal
The LIT turns a standard current or voltage signal into a proportional pulse string for totalising counters. It has 12 output ranges from 0 to 12.5 up to 0 to 51,200 counts per hour, accuracy of 0.05 % and repeatability of 0.01 %.
- Type
- Linear integrating totaliser, 4-wire
- Input
- Standard current or voltage process signal
- Output
- Pulse string proportional to the input
- Output ranges
- 12, from 0 to 12.5 through 0 to 51,200 counts per hour
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The LIT accepts a standard process current or voltage signal and produces a pulse string output proportional to it. The output can drive many kinds of totalising counters and can be scaled precisely to represent almost any engineering unit. Its 12 output ranges, from 0 to 12.5 through 0 to 51,200 counts per hour, give an accurate count in gallons, barrels, litres, tons, BTU or any other unit that measures the change of a process variable over time.
The unit can carry predetermining or totalising counters, such as the optional 8-digit LCD counter with manual or electronic reset, installed above the front panel. Other options are an attenuated input for high voltages (for example 0-10 Vdc), a raised zero input, front-panel range selection, additional outputs and RFI/EMI protection.
The -FS option adds a front-panel range switch covering the output ranges A1 through J. Units calibrate to within 0.05 % accuracy with 0.01 % repeatability. Count dropout is adjustable from 0.5 to 20 % of full scale, which stops false totalisation of unwanted low-level noise. Isolation between power and input-output is standard; input-output isolation comes with an optional relay output (-HS, -PR, -RE or -RR). The -RF option fits a filter against radio frequency interference.
The standard housing is a corrosion-resistant aluminium case approved by CSA, with a U-Back bracket for a 3 x 7-1/2 inch space. Other housings are a plug-in card for rack mounting, a panel mount housing and Eurocard plug-in housings. Enclosures to NEMA specifications are explosion-proof, fibreglass, oil-tight or watertight.
Technical specifications
| Type | Linear integrating totaliser, 4-wire |
|---|---|
| Input | Standard current or voltage process signal |
| Output | Pulse string proportional to the input |
| Output ranges | 12, from 0 to 12.5 through 0 to 51,200 counts per hour |
| Accuracy | Within 0.05 %, repeatability 0.01 % |
| Count dropout | Adjustable from 0.5 to 20 % of full scale |
| Options | 8-digit LCD counter, -FS, -RF, attenuated input, raised zero, relay outputs -HS, -PR, -RE, -RR |
| Isolation | Power from input-output; input-output with relay output |
| Housings | Aluminium U-Back 3 x 7-1/2 inch; plug-in; panel mount; Eurocard |
| Enclosures | Explosion-proof, fibreglass, oil-tight, watertight |
Part numbers
Show all part numbers (1)
LIT
How it compares with similar models
| Parameter | LIT 4-Wire Linear Integrating Totaliser, Pulse Output Proportional to the Input Signal | RBT 4-wire RTD transmitter, ±0.1% accuracy | MVT 4-Wire Millivolt Transmitter with Full Input, Output and Power Isolation | TCT isolated thermocouple transmitter, Eurocard (4-wire) |
|---|---|---|---|---|
| Type | Linear integrating totaliser, 4-wire | 4-wire RTD transmitter | Millivolt transmitter, 4-wire | — |
| Input | Standard current or voltage process signal | standard 2-, 3- or 4-wire RTD (platinum, copper, nickel) | Grounded or ungrounded millivolt signal | millivolt signal of any standard thermocouple |
| Output | Pulse string proportional to the input | proportional current | Current or voltage in a range of spans | standard current or voltage |
| Options | 8-digit LCD counter, -FS, -RF, attenuated input, raised zero, relay outputs -HS, -PR, -RE, -RR | -LNP, -LNN, -RO, -RF | — | -LNT, -RF, -DD |
| Isolation | Power from input-output; input-output with relay output | complete, input/output/power | Input, output and power isolated | input, output and power, transformer |
| Housings | Aluminium U-Back 3 x 7-1/2 inch; plug-in; panel mount; Eurocard | surface-mount; high-density plug-in card | Surface mount; plug-in card; EX | — |
Request a price and lead time
LIT 4-Wire Linear Integrating Totaliser, Pulse Output Proportional to the Input Signal. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the LIT output?
A pulse string proportional to the input current or voltage, for driving totalising counters.
How many output ranges does the LIT have?
Twelve, from 0 to 12.5 through 0 to 51,200 counts per hour.
How is noise kept out of the count?
Count dropout is adjustable from 0.5 to 20 % of full scale, so low-level noise is not totalised.