Q46R ORP monitor for water and process measurement
The Q46R measures oxidation-reduction potential (ORP, redox) and temperature continuously. It has advanced analogue outputs, relay control and EtherNet/IP, Modbus/RTU, Modbus/TCP and Profibus communications for water and process monitoring.
- Measured parameters
- ORP, temperature
- Outputs
- advanced analogue outputs, relay control
- Digital interfaces
- EtherNet/IP, Modbus/RTU, Modbus/TCP, Profibus
- Sensors
- conventional and differential pH/ORP, sealed reference system with a second glass pH electrode
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The Q46R is a monitor for continuous, high-accuracy measurement of oxidation-reduction potential (ORP, redox). Typical uses are drinking water treatment, environmental monitoring, municipal and industrial wastewater treatment, and industrial processes.
It measures ORP and temperature. Signals leave the instrument through advanced analogue outputs, relay control and digital communications. The supported protocols are EtherNet/IP, Modbus/RTU, Modbus/TCP and Profibus, so the monitor can serve as a local indicator or as a node in a control system.
The Q46P/R system is built to monitor pH as well as ORP. Differential pH/ORP sensors use a sealed reference system with a second glass pH electrode. This protects the sensor from destruction by chemical poisons such as cyanides, sulphides, chlorine and bisulphites. An integral preamplifier gives the sensor a low-impedance output, which keeps readings steady in varied media and allows a longer distance between sensor and analyser.
Calibration is simplified by automatic buffer recognition. Several sensor mounting options are offered, and the system accepts both conventional and differential pH sensors.
For maintenance, the Q-Blast option cleans the sensor automatically with an air blast and needs no operator action. That cuts manual cleaning at sites where the sensor fouls quickly.
The monitor is ordered as Q46R.
Technical specifications
| Measured parameters | ORP, temperature |
|---|---|
| Outputs | advanced analogue outputs, relay control |
| Digital interfaces | EtherNet/IP, Modbus/RTU, Modbus/TCP, Profibus |
| Sensors | conventional and differential pH/ORP, sealed reference system with a second glass pH electrode |
| Sensor signal | integral preamplifier, low-impedance output |
| Calibration | automatic buffer recognition |
| Sensor mounting | several options |
| Sensor cleaning | Q-Blast option, automatic air blast |
Part numbers
Show all part numbers (1)
Q46R
How it compares with similar models
| Parameter | Q46R ORP monitor for water and process measurement | BIMETAL dual-mode remote thermometer, 3-inch dial, 0-250°F or 0-500°F, mV or ohm output | 8801B gas moisture monitor with wall-mounted display unit, -100 to 20 °C dew point | Explosion-Proof Trace Oxygen Analyser 3020T, Range from 0-10 ppm |
|---|---|---|---|---|
| Outputs | advanced analogue outputs, relay control | — | isolated 4–20 mA, relays 3 A 250 V AC / 30 V DC | 0-1 V DC and 4-20 mA DC, isolated |
| Calibration | automatic buffer recognition | NIST traceable, up to 1% of reading, field adjustable | — | up to 0-25% |
Request a price and lead time
Q46R ORP monitor for water and process measurement. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What does the Q46R measure?
ORP (oxidation-reduction potential) and temperature.
Which digital interfaces does the Q46R support?
EtherNet/IP, Modbus/RTU, Modbus/TCP and Profibus, in addition to advanced analogue outputs and relay control.
Can the sensor be cleaned automatically?
Yes, the Q-Blast option cleans the sensor with an air blast without operator action.
Similar equipment from other manufacturers





![LXT 380 Explosion-Protected Liquid Transmitter, Ex db mb [ia IIC Ga] IIC T4 Gb](/media/kipia/lxt-380-explosion-proof-liquid-analysis-transmitter-1-640.webp)