YJV / YJLV / YJLHV power cables 6–35 kV with XLPE and PP insulation (including fire-resistant and water-blocking)

The manufacturer produces medium-voltage power cables of 6–35 kV with cross-linked polyethylene (XLPE) and polypropylene (PP) insulation. They are laid in distribution networks, internal networks of wind and solar plants, at industrial enterprises, in transport and in data centres. The company's cables operate, among others, at a big data processing base in Tianjin.

XLPE grades
YJV, YJLV, YJLHV, YJY, YJLY, YJLHY and armoured …22, …23, …32, …33
Conductors
copper, aluminium, aluminium alloy; 25–1600 mm²; 1 or 3 cores
PP insulation
6–35 kV, polypropylene without cross-linking, conductor temperature 90 °C, recyclable (Q/0900TDL111-2022, T/CEEIA 591-2022)
Fire-resistant
WDZB1N-(YJV, YJY…), class B1, copper with ρ ≤0.01700 Ω·mm²/m

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The main XLPE line covers the grades YJV, YJLV, YJLHV with a PVC sheath and YJY, YJLY, YJLHY with a polyethylene sheath. Armoured versions with tapes and wires are designated by the indices …22, …23, …32 and …33. The full range of armoured grades includes YJV22, YJLV22, YJLHV22, YJV23, YJLV23, YJLHV23, YJV32, YJLV32, YJLHV32, YJV33, YJLV33 and YJLHV33. Versions …22 and …23 have steel tape armour, …32 and …33 wire armour, and the second digit indicates a PVC or polyethylene sheath. Conductors of copper, aluminium or aluminium alloy have low resistivity and high permissible current load. Cross-sections are 25–1600 mm², in single- and three-core versions, including with reduced flammability.

The set of grades covers laying in ground, cable structures, in air and under mechanical loads. The cables are used in urban underground networks, at power plant outlets, for internal supply of industrial and mining enterprises and on submarine crossings of rivers and straits. For networks of wind and solar plants, industrial enterprises, transport and data centres, the grade is chosen by the laying method and the mechanical loads along the route.

Cables of 6–35 kV with polypropylene insulation are made to Q/0900TDL111-2022 and T/CEEIA 591-2022. The construction includes a stranded conductor, a conductor screen, polypropylene insulation, an insulation screen, a metal screen, a separating sheath, armour and an outer sheath. The permissible continuous conductor temperature is 90 °C. There is no cross-linking in production, so energy-intensive heating is not needed and emissions are lower. The thermoplastic material can be recycled many times, and the high purity of polypropylene keeps insulation quality stable.

Fire-resistant cables WDZB1N-(YJV, YJY, YJV22, YJV23, YJV32, YJV33) have the same armoured versions as the main line and flammability class B1. They remain operational during a fire and do not propagate flame. Conductors of oxygen-free copper have a resistivity of not more than 0.01700 Ω·mm²/m. Water-blocking cables FS-(YJV, YJLV, YJLHV…) are laid in damp soils and structures that may be flooded.

Technical specifications

XLPE gradesYJV, YJLV, YJLHV, YJY, YJLY, YJLHY and armoured …22, …23, …32, …33
Conductorscopper, aluminium, aluminium alloy; 25–1600 mm²; 1 or 3 cores
PP insulation6–35 kV, polypropylene without cross-linking, conductor temperature 90 °C, recyclable (Q/0900TDL111-2022, T/CEEIA 591-2022)
Fire-resistantWDZB1N-(YJV, YJY…), class B1, copper with ρ ≤0.01700 Ω·mm²/m
Water-blockingFS-(YJV, YJLV…)
Applicationdistribution networks, wind/solar plants, industry, data centres

Request a price and lead time

YJV / YJLV / YJLHV power cables 6–35 kV with XLPE and PP insulation (including fire-resistant and water-blocking). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8544 60 10 00
8544 60 90 00
HS, 6 digits8544 60
CN (EU)8544 60 10
8544 60 90
HTSUS (USA)8544 60 40 00
8544 60 60 00
China customs tariff8544 60 11 00
8544 60 19 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What cross-sections do YJV cables of 6–35 kV have?

From 25 to 1600 mm², single- or three-core, with conductors of copper, aluminium or aluminium alloy.

How does PP insulation differ from XLPE?

Polypropylene is not cross-linked, so production needs no energy-intensive heating, and the material can be recycled many times. The permissible continuous conductor temperature is 90 °C.

Which cables suit sites with fire safety requirements?

Fire-resistant WDZB1N-(YJV, YJY and armoured) of flammability class B1 remain operational during a fire and do not propagate flame.