International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SERV-RITE RTD lead wire, insulation range -200 to 1290°C, twisted copper conductors

Lead wire for connecting resistance temperature detectors to instruments and controllers. Insulation options span -200 to 1290°C, continuous ratings run from 105 to 480°C, and a metal overbraid can be added against abrasion.

Type
RTD lead wire
Insulation temperature range
-328 to 2350°F (-200 to 1290°C)
Continuous rating
220 to 900°F (105 to 480°C)
Conductors
Nickel or tin plated copper

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Twisted conductors are the starting point for any RTD lead wire, because a resistance measurement is quick to pick up electromagnetic interference over a long run. Every SERV-RITE RTD construction is twisted for that reason.

Conductors are nickel or tin plated copper, built as two, three or four-wire sets in a choice of gauge sizes. Insulation can be PVC, FEP, PFA or fibreglass, and colour coding follows ANSI requirements. A three-wire set compensates for lead resistance, while four-wire removes its effect entirely, so the choice depends on accuracy needs and the length of the run.

Across the range, insulation temperatures cover -200 to 1290°C (-328 to 2350°F), and continuous temperature ratings span 105 to 480°C (220 to 900°F), depending on the insulation chosen. Where the cable runs against steelwork or moving equipment, an optional metallic overbraid adds abrasion resistance.

The RTD lead wire sits in the same family as the thermocouple, extension and fibreglass wire, so a single specification can cover the whole sensor wiring of a furnace, oven or test rig. For an enquiry, list the number of conductors, gauge, insulation type, temperature along the route and whether overbraid is needed.

Technical specifications

TypeRTD lead wire
Insulation temperature range-328 to 2350°F (-200 to 1290°C)
Continuous rating220 to 900°F (105 to 480°C)
ConductorsNickel or tin plated copper
Wire countTwo, three or four-wire
InsulationPVC, FEP, PFA, fibreglass
ConstructionTwisted conductors
Colour codingANSI
OptionMetallic overbraid

Request a price and lead time

SERV-RITE RTD lead wire, insulation range -200 to 1290°C, twisted copper conductors. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which conductor counts are offered?

Two, three and four-wire constructions in nickel or tin plated copper.

What is the continuous temperature rating?

From 220 to 900°F (105 to 480°C), depending on the insulation.

Is abrasion protection available?

Yes, an optional metallic overbraid can be supplied.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides