International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SVM/SVMR electric globe valve actuators with integral controls, 10–100 Nm

SVM and SVMR are small electric globe valve actuators with integral controls and a bronze housing. Torque is 10 Nm to 100 Nm with a maximum of 16 turns per stroke, enclosure IP68. SVM is for open-close and positioning duty, SVMR for modulating duty.

Type
Electric globe valve actuator with integral controls
SVM duty
open-close and positioning (classes A and B), S2 - 15 min
SVMR duty
modulating (class C) S4 - 40%
Torque range
10 Nm - 100 Nm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SVM/SVMR range is a small electric globe valve actuator with its controls built in. All parameters are set directly at the actuator. The controls contain the switchgear, the power supply unit and the interface to the DCS, and they switch the actuator off automatically once the valve end position is reached, motor overheating is detected or a torque overload has occurred.

SVM actuators are designed for open-close duty and positioning duty (classes A and B), short-time duty S2 - 15 min. SVMR actuators are designed for modulating duty (class C) S4 - 40%. Torque is 10 Nm to 100 Nm, and a stroke can take a maximum of 16 turns.

All housing components are bronze and all external screws are stainless steel, which gives complete resistance to seawater even over a longer period. The brushless motor runs at variable speed, the actuator seats on limit and torque, and a handwheel is fitted for manual operation.

The enclosure is IP68 and corrosion protection is class KS; the ambient temperature range starts at -25 °C. Control inputs accept different voltages (DC/AC), output contacts are potential-free for status signalling, and a fieldbus interface is available. Local controls can be installed separately from the actuator as an option.

Technical specifications

TypeElectric globe valve actuator with integral controls
SVM dutyopen-close and positioning (classes A and B), S2 - 15 min
SVMR dutymodulating (class C) S4 - 40%
Torque range10 Nm - 100 Nm
Max. turns per stroke16
Enclosure protectionIP68
Corrosion protectionKS
Housingbronze; external screws stainless steel
Motorbrushless, variable speed
Interfacescontrol inputs DC/AC, potential-free output contacts, fieldbus

How it compares with similar models

ParameterSVM/SVMR electric globe valve actuators with integral controls, 10–100 NmSVC/SVCR electric globe valve actuators with integral controls, 10–100 NmSV+MEC electric globe valve actuators with separate controls, 10–100 NmSQ .2 part-turn actuators for open-close duty, 50–2500 Nm
TypeElectric globe valve actuator with integral controlsElectric globe valve actuator with integral controlsElectric globe valve actuator with separate MEC controlsPart-turn actuator
Torque range10 Nm - 100 Nm10 Nm - 100 Nm10 Nm - 100 Nm50 Nm - 2500 Nm
Enclosure protectionIP68IP68IP67/IP68IP68
Interfacescontrol inputs DC/AC, potential-free output contacts, fieldbuscontrol inputs DC/AC, potential-free output contacts, fieldbusmax. 4 binary inputs and outputs; options: 4 – 20 mA, analogue input for positioner—

Request a price and lead time

SVM/SVMR electric globe valve actuators with integral controls, 10–100 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many turns per stroke are allowed?

A maximum of 16 turns per stroke.

What separates SVM from SVMR?

SVM covers open-close and positioning duty (classes A and B, S2 - 15 min); SVMR covers modulating duty, class C, S4 - 40%.

What is the housing made of?

Bronze for all housing components and stainless steel for the external screws, which resists seawater.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides