SQ .2 part-turn actuators for open-close duty, 50–2500 Nm
The SQ .2 range covers part-turn valves with swing angles of 75 ° to 105 °. Torque is 50 Nm to 2500 Nm, operating time for 90° is 4 s to 100 s, and the enclosure is rated IP68. Duty types are open-close and positioning (classes A and B).
- Type
- Part-turn actuator
- Duty
- open-close and positioning (classes A and B), S2 - 15 min
- Torque range
- 50 Nm - 2500 Nm
- Operating time for 90°
- 4 s - 100 s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
SQ .2 actuators turn quarter-turn and other part-turn valves, with swing angles from 75 ° to 105 °. They are built for open-close duty and for positioning duty (classes A and B), with a short-time rating of S2 - 15 min. Output torque starts at 50 Nm and reaches 2500 Nm; a 90° stroke takes between 4 s and 100 s.
The actuator can be paired with different controls, from a plain OPEN-CLOSE unit to a micro-controlled version that logs operating data or carries a fieldbus interface.
Each unit senses limit positions and torque, runs on a 3-phase or 1-phase AC motor, and has a handwheel for manual operation and a mechanical position indicator. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -30 °C to +70 °C.
Optional equipment: intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter. For functional safety, selected configurations reach SIL 2, and SIL 3 is possible with AC 01.2 SIL actuator controls.
Electrical connection is made through the manufacturer's plug/socket connector, with terminals as an option, and cable entries come in several versions. The valve attachment follows DIN and ISO standards.
Technical specifications
| Type | Part-turn actuator |
|---|---|
| Duty | open-close and positioning (classes A and B), S2 - 15 min |
| Torque range | 50 Nm - 2500 Nm |
| Operating time for 90° | 4 s - 100 s |
| Swing angles | 75 ° - 105 ° |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C - +70 °C |
| Motors | 3-phase and 1-phase AC |
| Functional safety | up to SIL 2 in selected configurations; up to SIL 3 with AC 01.2 SIL controls |
| Valve attachment | according to DIN and ISO standards |
How it compares with similar models
| Parameter | SQ .2 part-turn actuators for open-close duty, 50–2500 Nm | SQR .2 part-turn actuators for modulating duty, 50–2500 Nm | SQV .2 variable-speed part-turn actuators for open-close duty, 150–2400 Nm | SQRV .2 variable-speed part-turn actuators for modulating duty |
|---|---|---|---|---|
| Type | Part-turn actuator | Part-turn actuator for modulating duty | Variable-speed part-turn actuator | Variable-speed part-turn actuator for modulating duty |
| Duty | open-close and positioning (classes A and B), S2 - 15 min | modulating (class C) S4 - 25 % | open-close and positioning (classes A and B), S2 - 15 min | modulating (class C) S4 - 25 % |
| Torque range | 50 Nm - 2500 Nm | 50 Nm - 2500 Nm | 150 Nm - 2400 Nm | 150 Nm - 2400 Nm |
| Operating time for 90° | 4 s - 100 s | 8 s - 100 s | 4 s - 360 s | 4 s - 360 s |
Request a price and lead time
SQ .2 part-turn actuators for open-close duty, 50–2500 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What torque and operating time does the SQ .2 offer?
Torque is 50 Nm to 2500 Nm and the operating time for 90° is 4 s to 100 s.
Which duty type is the SQ .2 designed for?
Open-close and positioning duty (classes A and B), short-time duty S2 - 15 min. Modulating duty is covered by the SQR .2 range.
Is functional safety to SIL available?
Up to SIL 2 in selected configurations, and up to SIL 3 combined with AC 01.2 SIL actuator controls.
Similar equipment from other manufacturers