SQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm
SQEx .2 is the explosion-proof version of the part-turn actuator for open-close duty. Torque is 50 Nm to 2400 Nm, operating time for 90° is 4 s to 100 s, enclosure IP68. ATEX, FM and IECEx markings apply to the range.
- Type
- Explosion-proof part-turn actuator
- Duty
- open-close
- Torque range
- 50 Nm - 2400 Nm
- Operating time for 90°
- 4 s - 100 s
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Explosion-proof devices are required in plants where a potentially explosive atmosphere is likely to occur. The SQEx .2 is built so that it cannot act as an ignition source: it produces neither ignition sparks nor hot surface temperatures. Certification is carried out in close collaboration with national and international certification bodies.
The ATEX marking reads II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3). The IECEx marking is Ex db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3). The FM marking is FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and FM CLASS III DIV 1 T4 (T3).
The actuator delivers 50 Nm to 2400 Nm and turns a valve through 90° in 4 s to 100 s, within swing angles of 75 ° to 105 °. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -30 °C to +40/+60 °C.
It has limit and torque sensing, a 3-phase AC motor, a handwheel for manual operation and a mechanical position indicator. Options are intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter. Functional safety reaches SIL 2 in selected configurations, and SIL 3 with ACExC 01.2 SIL actuator controls.
Connection is through the manufacturer's plug/socket connector (terminals optional) or cable entries, and the valve attachment follows DIN and ISO standards.
Technical specifications
| Type | Explosion-proof part-turn actuator |
|---|---|
| Duty | open-close |
| Torque range | 50 Nm - 2400 Nm |
| Operating time for 90° | 4 s - 100 s |
| Swing angles | 75 ° - 105 ° |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C - +40/+60 °C |
| ATEX marking | II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3) |
| FM marking | FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C) FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) FM CLASS III DIV 1 T4 (T3) |
| IECEx marking | Ex db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3) |
How it compares with similar models
| Parameter | SQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm | SQREx .2 explosion-proof part-turn actuators for modulating duty, 50–2400 Nm | SQVEx .2 explosion-proof variable-speed actuators for open-close duty, 150–2400 Nm | SQRVEx .2 explosion-proof variable-speed actuators for modulating duty |
|---|---|---|---|---|
| Type | Explosion-proof part-turn actuator | Explosion-proof part-turn actuator for modulating duty | Explosion-proof variable-speed part-turn actuator | Explosion-proof variable-speed actuator for modulating duty |
| Duty | open-close | modulating | open-close and positioning (classes A and B), S2 - 15 min | modulating (class C) S4 - 25 % |
| Torque range | 50 Nm - 2400 Nm | 50 Nm - 2400 Nm | 150 Nm - 2400 Nm | 150 Nm - 2400 Nm |
| Operating time for 90° | 4 s - 100 s | 8 s - 100 s | 4 s - 360 s | 4 s - 360 s |
Request a price and lead time
SQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What Ex marking does the SQEx .2 carry?
ATEX: II 2G Ex db eb IIC (IIB) T4 (T3) and II 2G Ex db IIC (IIB) T4 (T3). IECEx: Ex db eb IIC (IIB) T4 (T3) and Ex db IIC (IIB) T4 (T3).
What ambient temperature range applies?
-30 °C to +40/+60 °C.
Which duty is the SQEx .2 made for?
Open-close duty. Modulating duty is covered by the SQREx .2.