International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm

SQEx .2 is the explosion-proof version of the part-turn actuator for open-close duty. Torque is 50 Nm to 2400 Nm, operating time for 90° is 4 s to 100 s, enclosure IP68. ATEX, FM and IECEx markings apply to the range.

Type
Explosion-proof part-turn actuator
Duty
open-close
Torque range
50 Nm - 2400 Nm
Operating time for 90°
4 s - 100 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Explosion-proof devices are required in plants where a potentially explosive atmosphere is likely to occur. The SQEx .2 is built so that it cannot act as an ignition source: it produces neither ignition sparks nor hot surface temperatures. Certification is carried out in close collaboration with national and international certification bodies.

The ATEX marking reads II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3). The IECEx marking is Ex db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3). The FM marking is FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and FM CLASS III DIV 1 T4 (T3).

The actuator delivers 50 Nm to 2400 Nm and turns a valve through 90° in 4 s to 100 s, within swing angles of 75 ° to 105 °. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -30 °C to +40/+60 °C.

It has limit and torque sensing, a 3-phase AC motor, a handwheel for manual operation and a mechanical position indicator. Options are intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter. Functional safety reaches SIL 2 in selected configurations, and SIL 3 with ACExC 01.2 SIL actuator controls.

Connection is through the manufacturer's plug/socket connector (terminals optional) or cable entries, and the valve attachment follows DIN and ISO standards.

Technical specifications

TypeExplosion-proof part-turn actuator
Dutyopen-close
Torque range50 Nm - 2400 Nm
Operating time for 90°4 s - 100 s
Swing angles75 ° - 105 °
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C - +40/+60 °C
ATEX markingII 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3)
FM markingFM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C) FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) FM CLASS III DIV 1 T4 (T3)
IECEx markingEx db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3)

How it compares with similar models

ParameterSQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 NmSQREx .2 explosion-proof part-turn actuators for modulating duty, 50–2400 NmSQVEx .2 explosion-proof variable-speed actuators for open-close duty, 150–2400 NmSQRVEx .2 explosion-proof variable-speed actuators for modulating duty
TypeExplosion-proof part-turn actuatorExplosion-proof part-turn actuator for modulating dutyExplosion-proof variable-speed part-turn actuatorExplosion-proof variable-speed actuator for modulating duty
Dutyopen-closemodulatingopen-close and positioning (classes A and B), S2 - 15 minmodulating (class C) S4 - 25 %
Torque range50 Nm - 2400 Nm50 Nm - 2400 Nm150 Nm - 2400 Nm150 Nm - 2400 Nm
Operating time for 90°4 s - 100 s8 s - 100 s4 s - 360 s4 s - 360 s

Request a price and lead time

SQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What Ex marking does the SQEx .2 carry?

ATEX: II 2G Ex db eb IIC (IIB) T4 (T3) and II 2G Ex db IIC (IIB) T4 (T3). IECEx: Ex db eb IIC (IIB) T4 (T3) and Ex db IIC (IIB) T4 (T3).

What ambient temperature range applies?

-30 °C to +40/+60 °C.

Which duty is the SQEx .2 made for?

Open-close duty. Modulating duty is covered by the SQREx .2.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides