International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SQVEx .2 explosion-proof variable-speed actuators for open-close duty, 150–2400 Nm

SQVEx .2 is an electric part-turn actuator with variable operating time, certified for potentially explosive atmospheres. Torque is 150 Nm to 2400 Nm, a 90° stroke takes 4 s to 360 s, and the duty is open-close and positioning (classes A and B).

Type
Explosion-proof variable-speed part-turn actuator
Duty
open-close and positioning (classes A and B), S2 - 15 min
Torque range
150 Nm - 2400 Nm
Operating time for 90°
4 s - 360 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The SQVEx .2 combines a variable operating time with certification for use in potentially explosive atmospheres. It is designed for open-close duty and positioning duty (classes A and B), short-time duty S2 - 15 min.

The ATEX marking is II 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3). The IECEx marking is Ex db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3). For FM the entries are FM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C), FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) and FM CLASS III DIV 1 T4 (T3).

Output torque is 150 Nm to 2400 Nm. A 90° stroke takes 4 s to 360 s within swing angles of 75 ° to 105 °. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -30 °C to +40/+60 °C.

Mains connection is 1-phase or 3-phase. The actuator senses limit positions and torque, and has a handwheel and a mechanical position indicator. Options: intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter.

Functions include programmable potential-free output contacts, soft start and stop, an operating time profile that avoids pressure surges, and separate operating times for EMERGENCY and safety behaviour. A process controller (PID), fieldbus control and operation data logging are also included, and a Bluetooth interface links a notebook or an Android tablet. Connection is by plug/socket connector or cable entries; valve attachments follow DIN and ISO standards.

Technical specifications

TypeExplosion-proof variable-speed part-turn actuator
Dutyopen-close and positioning (classes A and B), S2 - 15 min
Torque range150 Nm - 2400 Nm
Operating time for 90°4 s - 360 s
Swing angles75 ° - 105 °
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C - +40/+60 °C
Mains connection1-phase and 3-phase
Functionsprogrammable potential-free output contacts, soft start and stop, operating time profile, process controller (PID), fieldbus control, data logging, Bluetooth
ATEX markingII 2G Ex db eb IIC (IIB) T4 (T3) II 2G Ex db IIC (IIB) T4 (T3)
FM markingFM CLASS I DIV 1 GROUPS (B), C, D T4 (T3C) FM CLASS II DIV 1 GROUPS E, F, G T4 (T3C) FM CLASS III DIV 1 T4 (T3)
IECEx markingEx db eb IIC (IIB) T4 (T3) Ex db IIC (IIB) T4 (T3)

How it compares with similar models

ParameterSQVEx .2 explosion-proof variable-speed actuators for open-close duty, 150–2400 NmSQRVEx .2 explosion-proof variable-speed actuators for modulating dutySQV .2 variable-speed part-turn actuators for open-close duty, 150–2400 NmSQEx .2 explosion-proof part-turn actuators for open-close duty, 50–2400 Nm
TypeExplosion-proof variable-speed part-turn actuatorExplosion-proof variable-speed actuator for modulating dutyVariable-speed part-turn actuatorExplosion-proof part-turn actuator
Dutyopen-close and positioning (classes A and B), S2 - 15 minmodulating (class C) S4 - 25 %open-close and positioning (classes A and B), S2 - 15 minopen-close
Torque range150 Nm - 2400 Nm150 Nm - 2400 Nm150 Nm - 2400 Nm50 Nm - 2400 Nm
Operating time for 90°4 s - 360 s4 s - 360 s4 s - 360 s4 s - 100 s
Ambient temperature-30 °C - +40/+60 °C-30 °C - +40/+60 °C-30 °C - +70 °C-30 °C - +40/+60 °C

Request a price and lead time

SQVEx .2 explosion-proof variable-speed actuators for open-close duty, 150–2400 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What Ex marking does the SQVEx .2 carry?

ATEX: II 2G Ex db eb IIC (IIB) T4 (T3) and II 2G Ex db IIC (IIB) T4 (T3). IECEx: Ex db eb IIC (IIB) T4 (T3) and Ex db IIC (IIB) T4 (T3).

What ambient temperature range applies?

-30 °C to +40/+60 °C.

How long does a 90° stroke take?

4 s to 360 s, at a torque of 150 Nm to 2400 Nm.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides