International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SQR .2 part-turn actuators for modulating duty, 50–2500 Nm

The SQR .2 range is the modulating version of the part-turn actuator, rated for class C duty S4 - 25 %. Torque is 50 Nm to 2500 Nm, modulating torque 75 Nm to 1200 Nm, with up to 1500 starts per hour and 8 s to 100 s for 90°.

Type
Part-turn actuator for modulating duty
Duty
modulating (class C) S4 - 25 %
Torque range
50 Nm - 2500 Nm
Modulating torque range
75 Nm - 1200 Nm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

SQR .2 actuators are the part-turn type for regulating valves. They are designed for modulating duty, class C, S4 - 25 %. Output torque is 50 Nm to 2500 Nm, of which 75 Nm to 1200 Nm applies to modulating operation, and the maximum number of starts is 1500 c/h.

A 90° stroke takes 8 s to 100 s, and swing angles run from 75 ° to 105 °. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -30 °C to +70 °C.

As with the other actuators of this family, the controls can be chosen freely: a simple OPEN-CLOSE unit, or a micro-controlled version that logs operating data or has a fieldbus interface.

Each actuator senses limit positions and torque, runs on a 3-phase or 1-phase AC motor, and carries a handwheel and a mechanical position indicator. Intermediate position switches, switches in tandem version, a position transmitter and a magnetic limit and torque transmitter can be added.

Selected configurations reach SIL 2, and SIL 3 is possible with AC 01.2 SIL actuator controls. Electrical connection is through the manufacturer's plug/socket connector, with terminals as an option, or through cable entries; valve attachments follow DIN and ISO standards.

Technical specifications

TypePart-turn actuator for modulating duty
Dutymodulating (class C) S4 - 25 %
Torque range50 Nm - 2500 Nm
Modulating torque range75 Nm - 1200 Nm
Number of starts (max.)1500 c/h
Operating time for 90°8 s - 100 s
Swing angles75 ° - 105 °
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C - +70 °C
Functional safetyup to SIL 2 in selected configurations; up to SIL 3 with AC 01.2 SIL

How it compares with similar models

ParameterSQR .2 part-turn actuators for modulating duty, 50–2500 NmSQ .2 part-turn actuators for open-close duty, 50–2500 NmSQREx .2 explosion-proof part-turn actuators for modulating duty, 50–2400 NmSQRV .2 variable-speed part-turn actuators for modulating duty
TypePart-turn actuator for modulating dutyPart-turn actuatorExplosion-proof part-turn actuator for modulating dutyVariable-speed part-turn actuator for modulating duty
Dutymodulating (class C) S4 - 25 %open-close and positioning (classes A and B), S2 - 15 minmodulatingmodulating (class C) S4 - 25 %
Torque range50 Nm - 2500 Nm50 Nm - 2500 Nm50 Nm - 2400 Nm150 Nm - 2400 Nm
Modulating torque range75 Nm - 1200 Nm—75 Nm - 1200 Nm52 Nm - 840 Nm
Operating time for 90°8 s - 100 s4 s - 100 s8 s - 100 s4 s - 360 s
Ambient temperature-30 °C - +70 °C-30 °C - +70 °C-30 °C - +40/+60 °C-30 °C - +70 °C

Request a price and lead time

SQR .2 part-turn actuators for modulating duty, 50–2500 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How many starts per hour does the SQR .2 allow?

Up to 1500 c/h.

Which duty class applies?

Modulating duty, class C, S4 - 25 %, with a modulating torque of 75 Nm to 1200 Nm.

Which controls can be combined with the SQR .2?

Anything from a simple OPEN-CLOSE unit to a micro-controlled version with operating data logging or a fieldbus interface.