SVC/SVCR electric globe valve actuators with integral controls, 10–100 Nm
SVC and SVCR are the small electric actuators for globe valves, with integral controls. Torque is 10 Nm to 100 Nm and output speed is 0.6 1/min to 22 1/min. SVC is made for open-close and positioning duty, SVCR for modulating duty.
- Type
- Electric globe valve actuator with integral controls
- SVC duty
- open-close and positioning (classes A and B), S2 - 15 min
- SVCR duty
- modulating (class C) S4 - 40%
- Torque range
- 10 Nm - 100 Nm
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The SVC/SVCR series covers the lower torque end of the electric globe valve actuators. The controls are built in and contain the switchgear, the power supply unit and the interface to the DCS. All parameters are set directly at the actuator. The controls switch the actuator off automatically when the valve end position is reached, when motor overheating is detected and when a torque overload occurs.
SVC actuators are designed for open-close duty and positioning duty (classes A and B), short-time duty S2 - 15 min. SVCR actuators are designed for modulating duty, class C, S4 - 40%. Torque is 10 Nm to 100 Nm and output speeds are 0.6 1/min to 22 1/min, with a maximum of 99 turns per stroke (limited stem stroke).
All housing parts are made of aluminium, which keeps the weight low. The brushless motor runs at variable speed, and a handwheel is fitted for manual operation. The actuator seats on limit and torque. The enclosure is IP68, corrosion protection is class KS, and the ambient temperature range is -25 °C to +70 °C.
Control inputs accept different voltages (DC/AC). Status is signalled through potential-free output contacts, and a fieldbus interface is available. Local controls can be mounted separately from the actuator as an option.
Technical specifications
| Type | Electric globe valve actuator with integral controls |
|---|---|
| SVC duty | open-close and positioning (classes A and B), S2 - 15 min |
| SVCR duty | modulating (class C) S4 - 40% |
| Torque range | 10 Nm - 100 Nm |
| Output speeds | 0.6 1/min - 22 1/min |
| Turns per stroke | max. 99 (limited stem stroke) |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -25 °C - +70 °C |
| Motor | brushless, variable speed |
| Housing | aluminium |
| Interfaces | control inputs DC/AC, potential-free output contacts, fieldbus |
How it compares with similar models
| Parameter | SVC/SVCR electric globe valve actuators with integral controls, 10–100 Nm | SVM/SVMR electric globe valve actuators with integral controls, 10–100 Nm | SV+MEC electric globe valve actuators with separate controls, 10–100 Nm | SQ .2 part-turn actuators for open-close duty, 50–2500 Nm |
|---|---|---|---|---|
| Type | Electric globe valve actuator with integral controls | Electric globe valve actuator with integral controls | Electric globe valve actuator with separate MEC controls | Part-turn actuator |
| Torque range | 10 Nm - 100 Nm | 10 Nm - 100 Nm | 10 Nm - 100 Nm | 50 Nm - 2500 Nm |
| Enclosure protection | IP68 | IP68 | IP67/IP68 | IP68 |
| Ambient temperature | -25 °C - +70 °C | — | -25 °C - +70 °C | -30 °C - +70 °C |
| Interfaces | control inputs DC/AC, potential-free output contacts, fieldbus | control inputs DC/AC, potential-free output contacts, fieldbus | max. 4 binary inputs and outputs; options: 4 – 20 mA, analogue input for positioner | — |
Request a price and lead time
SVC/SVCR electric globe valve actuators with integral controls, 10–100 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the difference between SVC and SVCR?
SVC is for open-close and positioning duty (S2 - 15 min), SVCR for modulating duty, class C, S4 - 40%.
What do the integral controls contain?
Switchgear, a power supply unit and the interface to the DCS. All parameters are set directly at the actuator.
When does the actuator switch off automatically?
When the valve end position is reached, when motor overheating is detected or when a torque overload occurs.
Similar equipment from other manufacturers