International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SV+MEC electric globe valve actuators with separate controls, 10–100 Nm

SV+MEC pairs a small electric globe valve actuator with separate MEC controls. Torque is 10 Nm to 100 Nm, output speed 0.6 1/min to 22 1/min, enclosure IP67/IP68. The bronze actuator housing is resistant to seawater.

Type
Electric globe valve actuator with separate MEC controls
Duty
open-close and positioning (classes A and B), S2 - 15 min; modulating (class C) S4 - 40%
Torque range
10 Nm - 100 Nm
Output speeds
0.6 1/min - 22 1/min

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

In the SV+MEC range the controls are not part of the actuator but sit in a separate MEC unit. All parameters are set directly at the MEC controls. They contain the switchgear, the power supply unit and the interface to the DCS, and they switch the actuator off automatically when the valve end position is reached, when motor overheating is detected and when a torque overload occurs.

The actuators are designed for open-close duty and positioning duty (classes A and B), short-time duty S2 - 15 min, with a variant for modulating duty (class C) S4 - 40%. Torque is 10 Nm to 100 Nm and output speeds are 0.6 1/min to 22 1/min. The brushless motor runs at variable speed, the actuator seats on limit and torque, and a handwheel is provided.

All housing components of the actuator are bronze and all external screws are stainless steel, which gives complete resistance to seawater even over a longer period. The MEC housing is aluminium with the manufacturer's powder coating. Shock proof tests for the military shipbuilding industry are part of the feature set.

The enclosure is IP67/IP68 and the ambient temperature range is -25 °C to +70 °C. The interface offers a maximum of 4 binary inputs and outputs with configurable signal assignment. A 4 – 20 mA position feedback and an analogue input for a positioner are options, as are local controls at the MEC.

Technical specifications

TypeElectric globe valve actuator with separate MEC controls
Dutyopen-close and positioning (classes A and B), S2 - 15 min; modulating (class C) S4 - 40%
Torque range10 Nm - 100 Nm
Output speeds0.6 1/min - 22 1/min
Enclosure protectionIP67/IP68
Ambient temperature-25 °C - +70 °C
Motorbrushless, variable speed
Actuator housingbronze; external screws stainless steel
MEC housingaluminium with powder coating
Interfacesmax. 4 binary inputs and outputs; options: 4 – 20 mA, analogue input for positioner

How it compares with similar models

ParameterSV+MEC electric globe valve actuators with separate controls, 10–100 NmSVC/SVCR electric globe valve actuators with integral controls, 10–100 NmSVM/SVMR electric globe valve actuators with integral controls, 10–100 NmTIGRON-M explosion-proof multi-turn actuators, 10–1000 Nm
TypeElectric globe valve actuator with separate MEC controlsElectric globe valve actuator with integral controlsElectric globe valve actuator with integral controlsExplosion-proof multi-turn actuator
Torque range10 Nm - 100 Nm10 Nm - 100 Nm10 Nm - 100 Nm10 Nm - 1000 Nm
Output speeds0.6 1/min - 22 1/min0.6 1/min - 22 1/min—4 1/min - 216 1/min
Enclosure protectionIP67/IP68IP68IP68IP68
Ambient temperature-25 °C - +70 °C-25 °C - +70 °C—-65 °C - +75 °C
Interfacesmax. 4 binary inputs and outputs; options: 4 – 20 mA, analogue input for positionercontrol inputs DC/AC, potential-free output contacts, fieldbuscontrol inputs DC/AC, potential-free output contacts, fieldbusProfibus, Modbus

Request a price and lead time

SV+MEC electric globe valve actuators with separate controls, 10–100 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Is the SV+MEC suited to seawater?

Yes. The housing is bronze and the external screws are stainless steel, giving complete resistance to seawater even over a longer period.

Where are the controls?

In the separate MEC unit, which holds the switchgear, power supply unit and DCS interface, and where all parameters are set.

What inputs and outputs are available?

A maximum of 4 binary inputs and outputs with configurable assignment, plus optional 4 – 20 mA position feedback and an analogue input for a positioner.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides