Generators for NPP emergency diesel generators (class K3 / IEEE 1E), 1–20 MW, 380 V – 15 kV
Self-excited synchronous generators for emergency and standby diesel generators of nuclear power plants. Power is 1 to 20 MW, voltage 380 V to 15 kV, for medium- and high-speed diesel engines. Built to RCCE class K3 requirements or IEEE 1E classification, supplied with analogue voltage regulators.
- Power
- 1–20 MW
- Voltage
- 380 V – 15 kV
- Type
- self-excited synchronous generators, medium- and high-speed
- Excitation
- AREP with permanent magnet inductor (PMI), PMG on request
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
These are self-excited synchronous generators for emergency and standby diesel generators of nuclear power plants. Power ranges from 1 to 20 MW, voltage from 380 V to 15 kV, and they are driven by medium- and high-speed diesel engines. Such sets must start and take on the load of the safety systems on loss of external power supply to the plant, so the generators are subject to qualification requirements, and type tests alone are not enough. The generators are supplied with analogue voltage regulators. The manufacturer classes this field as special, because separate nuclear industry requirements for quality, personnel training and documentation apply to it.
The generators are built to RCCE class K3 requirements or IEEE 1E classification, with qualification of service life for 40 or 60 years. The manufacturer carries out the seismic qualification of the generator itself. Excitation is an AREP system with auxiliary windings and a permanent magnet inductor (PMI), PMG on request. Regulation is by a single analogue voltage regulator or a cabinet with two regulators, qualified to RCCE K3.
The quality management system is certified to ISO 9001 and ISO 14001. Nuclear activity complies with the international IAEA quality standards (IAEA-50-C-Q, GS-R-3) and EDF SGAQ requirements. Personnel engaged in nuclear projects receive separate safety culture training, and the main customers and operating organisations regularly carry out audits. Each order is assigned a project manager, who follows it from technical requirements to delivery and the service programme. The project manager is responsible for deadlines, delivery of qualification documentation, customer inspections, acceptance with the participation of an inspectorate, and the end of manufacturing report. Qualification documentation is included in the scope of supply.
The manufacturer's references cover France (EDF DUS/CCL and FARN projects), China (Sanmen AP1000, Haiyang AP1000, Ningde, Hongyanhe, Qinshan 2, Ling Ao), India (Kudankulam), Korea (Wolsong 2, 3 and 4), Romania (Cernavoda) and Sweden (Ringhals, Oskarshamn OKG2). The list of sites shows the geography of supply from European to Asian nuclear plants. The generators are considered for replacement of equipment of NPP emergency diesel generator stations by purpose, power and qualification class.
Technical specifications
| Power | 1–20 MW |
|---|---|
| Voltage | 380 V – 15 kV |
| Type | self-excited synchronous generators, medium- and high-speed |
| Excitation | AREP with permanent magnet inductor (PMI), PMG on request |
| Qualification | RCCE K3 or IEEE class 1E; seismic qualification |
| Service life | qualification for 40 or 60 years |
| Regulator | analogue, single or double regulator cabinet with RCCE K3 qualification |
| Quality | ISO 9001, ISO 14001; IAEA-50-C-Q, GS-R-3; EDF SGAQ |
Request a price and lead time
Generators for NPP emergency diesel generators (class K3 / IEEE 1E), 1–20 MW, 380 V – 15 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What power and voltage do generators for NPP emergency diesel generators have?
Power is from 1 to 20 MW and voltage from 380 V to 15 kV. These are self-excited synchronous generators for medium- and high-speed diesel engines.
What requirements are these generators qualified to?
RCCE class K3 requirements or IEEE 1E classification, with qualification of service life for 40 or 60 years. The manufacturer carries out the seismic qualification of the generator itself.
What excitation and voltage regulation system is used?
AREP excitation with a permanent magnet inductor (PMI), PMG on request. Regulation is by a single analogue regulator or a cabinet with two regulators qualified to RCCE K3.