Motor-generator sets for power transformer test laboratories

Motor-generator sets are intended for high-voltage and high-power test laboratories, primarily for factory test benches for power transformers.

Output voltage frequency
50 / 60 / 200 Hz
Purpose
induced-voltage test (ACSD), partial discharge, short-circuit power
Transformers under test
three-phase and single-phase, power up to ≈20× the generator power
Features
reinforced damper winding, very low total harmonic distortion (THD)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Motor-generator sets are intended for high-voltage and high-power test laboratories, primarily for factory test benches for power transformers. They serve as a power source at a frequency of 50, 60 or 200 Hz for induced-voltage testing and partial discharge measurement, for obtaining short-circuit power during transformer tests and, on request, circuit breaker tests, and in special cases for storing kinetic energy with an additional flywheel. Short-duration induced-voltage testing (ACSD) and partial discharge measurement are the most important checks of the insulation integrity of a transformer. They require a voltage as close as possible to sinusoidal and a frequency usually about twice the rated one, so that the magnetic core does not saturate at a test voltage above the rated one. The main requirement for the generators is therefore the lowest achievable total harmonic distortion (THD), so that the measurement results reflect the properties of the transformer rather than the harmonics of the source. The generators operate in a mode close to that of a synchronous compensator, which provides the necessary reactive power and voltage regulation quality; operating experience shows that transformers with a power about 20 times the rated power of the generator can be tested. For tests of both three-phase and single-phase transformers on one bench, the damper winding is reinforced: with a single-phase load the negative-sequence stator current induces in it a current of double frequency, much larger than under symmetrical load. The standard scope of supply includes a group of rotating machines with drive motor and generator, an oil system, a frequency converter with step-up and/or step-down transformers, excitation electronics, protection relays, current transformers, installation of the machines and commissioning of the excitation and protection systems. The design is adapted to the existing laboratory configuration; 3D design and modelling, factory tests of the generator and on-site measurement support are carried out. The Intelligent Solutions monitoring system and round-the-clock service are available.

Technical specifications

Output voltage frequency50 / 60 / 200 Hz
Purposeinduced-voltage test (ACSD), partial discharge, short-circuit power
Transformers under testthree-phase and single-phase, power up to ≈20× the generator power
Featuresreinforced damper winding, very low total harmonic distortion (THD)
Scope of supplydrive motor, generator, oil system, frequency converter with transformers, excitation, protection relays, current transformers
Optionsflywheel for storing kinetic energy

Request a price and lead time

Motor-generator sets for power transformer test laboratories. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides