International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

M-Line modular Kaplan, Francis, Pelton hydro units for small hydropower plants up to 4.75 MW

M-Line is a modular line of standardised hydro units for small hydropower plants, comprising Kaplan up to 1000 kW, Francis up to 1700 kW and Pelton up to 4750 kW. The unit is supplied on a water-to-wire basis, pre-assembled on a mounting frame. Delivery times are shortened by up to 30 %.

M-Line Kaplan
vertical, double regulation; head 2–10 m, flow 2–20 m³/s, up to 1000 kW
M-Line Francis
horizontal, guide vane regulation; head 20–80 m, flow 0.25–3.8 m³/s, up to 1700 kW; sizes FHM-1…FHM-6
M-Line Pelton
vertical, 3–6 nozzles, jet deflector; head 80–340 m, flow 0.4–1.6 m³/s, up to 4750 kW; sizes Small/Medium
Generator
synchronous, direct coupling (Kaplan: gearbox optional)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

M-Line is a modular line of standardised hydro units for small hydropower plants. It is designed for new run-of-river stations, refurbishment of existing low-head sites and energy recovery facilities. The unit is supplied on a water-to-wire basis. This is a simplified and maximally standardised turbine-generator pair with auxiliary systems, integrated automation and actuators, pre-assembled on a mounting frame. This scheme shortens delivery times by up to 30 %, speeds up installation and commissioning, and reduces powerhouse size and construction costs.

Manufacture and testing follow the manufacturer's global standards, and the small hydropower division is located in St. Pölten (Austria). M-Line Kaplan is vertical, double-regulated (guide vanes and runner blades), with a synchronous generator on the same shaft, a gearbox being optional. Head 2–10 m, flow 2–20 m³/s, power up to 1000 kW.

M-Line Francis is horizontal, regulated by guide vanes, with a high-quality runner and standardised steel parts. Head 20–80 m, flow 0.25–3.8 m³/s, power up to 1700 kW. There are six sizes FHM-1…FHM-6 with predefined dimensions of the inlet, turbine and draft tube modules. M-Line Pelton is vertical and compact, with 3–6 nozzles and a jet deflector for load rejection. Head 80–340 m, flow 0.4–1.6 m³/s, power up to 4750 kW. Sizes Small and Medium, with generator, housing, hydraulic power unit and inlet valve modules.

The electrical part (e-BoP) is included in the supply. The standard low- and medium-voltage platform for all M-Line units includes a low-voltage switchgear, unit and line protection, synchronisation, plant-wide control, an automatic voltage regulator, AC and DC auxiliary supply, alarm signalling and remote monitoring. Island mode, UPS, variable speed and containerised versions are available as options. The manufacturer provides dimensions for designing the hydropower plant building from the first stage.

References. Floresti 1 (Romania), horizontal Francis 761 kW at 30.7 m head. Babino Polje (Montenegro), vertical Pelton units with 3 and 6 nozzles, 1640 and 618 kW at heads of 186 and 174 m.

Technical specifications

M-Line Kaplanvertical, double regulation; head 2–10 m, flow 2–20 m³/s, up to 1000 kW
M-Line Francishorizontal, guide vane regulation; head 20–80 m, flow 0.25–3.8 m³/s, up to 1700 kW; sizes FHM-1…FHM-6
M-Line Peltonvertical, 3–6 nozzles, jet deflector; head 80–340 m, flow 0.4–1.6 m³/s, up to 4750 kW; sizes Small/Medium
Generatorsynchronous, direct coupling (Kaplan: gearbox optional)
Automationstandard LV/MV platform: LV switchgear, protection, synchronisation, AVR, AC/DC auxiliary supply
Delivery timereduced by up to 30 % through standardisation and pre-assembly

Request a price and lead time

M-Line modular Kaplan, Francis, Pelton hydro units for small hydropower plants up to 4.75 MW. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What head and power range do M-Line units cover?

Kaplan works at a head of 2–10 m up to 1000 kW, Francis at 20–80 m up to 1700 kW, Pelton at 80–340 m up to 4750 kW.

What does the e-BoP electrical part include?

Low-voltage switchgear, unit and line protection, synchronisation, plant-wide control, an automatic voltage regulator, auxiliary supply and remote monitoring.

What sizes do Francis and Pelton come in?

Francis has six sizes FHM-1…FHM-6. Pelton is built in sizes Small and Medium, with 3–6 nozzles.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides