International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

LCT/MJT, LRT/MJRT — low-voltage hydro-generators up to 690 V, up to 5,500 kVA

LCT/MJT and LRT/MJRT are low-voltage synchronous hydro-generators for small hydropower plants, diversion and run-of-river stations, as well as small stations on water conduits and treatment facilities.

Power
up to 4,500 kVA (LCT/MJT, IC01; announced: up to 5,200 kVA); up to 5,500 kVA (LRT/MJRT, IC81W; announced: up to 5,000 kVA)
Voltage
up to 690 V
Frequency
50/60 Hz
Number of poles
4–20 (more on request)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

LCT/MJT and LRT/MJRT are low-voltage synchronous hydro-generators for small hydropower plants, diversion and run-of-river stations, as well as small stations on water conduits and treatment facilities. The generators work with Cross-Flow, Francis, Kaplan, Pelton and Turgo turbines and are built with horizontal or vertical shafts. LCT/MJT is an open design with self-ventilation IC01: power up to 4,500 kVA (series announcement: up to 5,200 kVA), voltage up to 690 V, frequency 50/60 Hz, 4–20 poles (more on agreement), frame sizes 315–900, degree of protection IP23, ambient temperature −15…+60 °C. LRT/MJRT is a closed design with an air-water cooler IC81W: up to 5,500 kVA (announced: up to 5,000 kVA), up to 690 V, IP44 (IP56 on request), ambient 0…+60 °C, water up to 40 °C. Voltage regulator: E-Vo up to frame size 630, MGC II above. Rolling bearings; sliding bearings from frame size 400 on request. Standard IEC 60034; UL/CSA on request. The low-voltage design allows the generator to be connected to the network through a standard 0.4/10 kV step-up transformer and to use low-voltage switchgear. The item is suitable for small hydropower plants in Ukraine with capacities of up to several megawatts.

Technical specifications

Powerup to 4,500 kVA (LCT/MJT, IC01; announced: up to 5,200 kVA); up to 5,500 kVA (LRT/MJRT, IC81W; announced: up to 5,000 kVA)
Voltageup to 690 V
Frequency50/60 Hz
Number of poles4–20 (more on request)
Frame size315–900
Degree of protectionIP23 (LCT/MJT); IP44, IP56 on request (LRT/MJRT)
RegulatorE-Vo up to frame size 630, MGC II above
Bearingsrolling; sliding on request from frame size 400
TurbinesCross-Flow, Francis, Kaplan, Pelton, Turgo
StandardIEC 60034

Request a price and lead time

LCT/MJT, LRT/MJRT — low-voltage hydro-generators up to 690 V, up to 5,500 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides