LCT/MJT, LRT/MJRT — low-voltage hydro-generators up to 690 V, up to 5,500 kVA
LCT/MJT and LRT/MJRT are low-voltage synchronous hydro-generators for small hydropower plants, diversion and run-of-river stations, as well as small stations on water conduits and treatment facilities.
- Power
- up to 4,500 kVA (LCT/MJT, IC01; announced: up to 5,200 kVA); up to 5,500 kVA (LRT/MJRT, IC81W; announced: up to 5,000 kVA)
- Voltage
- up to 690 V
- Frequency
- 50/60 Hz
- Number of poles
- 4–20 (more on request)
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
LCT/MJT and LRT/MJRT are low-voltage synchronous hydro-generators for small hydropower plants, diversion and run-of-river stations, as well as small stations on water conduits and treatment facilities. The generators work with Cross-Flow, Francis, Kaplan, Pelton and Turgo turbines and are built with horizontal or vertical shafts. LCT/MJT is an open design with self-ventilation IC01: power up to 4,500 kVA (series announcement: up to 5,200 kVA), voltage up to 690 V, frequency 50/60 Hz, 4–20 poles (more on agreement), frame sizes 315–900, degree of protection IP23, ambient temperature −15…+60 °C. LRT/MJRT is a closed design with an air-water cooler IC81W: up to 5,500 kVA (announced: up to 5,000 kVA), up to 690 V, IP44 (IP56 on request), ambient 0…+60 °C, water up to 40 °C. Voltage regulator: E-Vo up to frame size 630, MGC II above. Rolling bearings; sliding bearings from frame size 400 on request. Standard IEC 60034; UL/CSA on request. The low-voltage design allows the generator to be connected to the network through a standard 0.4/10 kV step-up transformer and to use low-voltage switchgear. The item is suitable for small hydropower plants in Ukraine with capacities of up to several megawatts.
Technical specifications
| Power | up to 4,500 kVA (LCT/MJT, IC01; announced: up to 5,200 kVA); up to 5,500 kVA (LRT/MJRT, IC81W; announced: up to 5,000 kVA) |
|---|---|
| Voltage | up to 690 V |
| Frequency | 50/60 Hz |
| Number of poles | 4–20 (more on request) |
| Frame size | 315–900 |
| Degree of protection | IP23 (LCT/MJT); IP44, IP56 on request (LRT/MJRT) |
| Regulator | E-Vo up to frame size 630, MGC II above |
| Bearings | rolling; sliding on request from frame size 400 |
| Turbines | Cross-Flow, Francis, Kaplan, Pelton, Turgo |
| Standard | IEC 60034 |