KT-CLH — emergency diesel generator sets in cubicle enclosure, 6600 V, 300–1250 kVA
Emergency diesel generator sets in cubicle (enclosure) design for 6600 V are intended for standby power supply of large buildings and facilities fed at medium voltage: hospitals, public institutions, banks, data centres and power stations.
- Voltage
- 6600 V
- Power
- 300/320 – 1000/1250 kVA (50/60 Hz)
- Generator poles
- 4
- Example
- KT-700CLH 6600 V 625/700 kVA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Emergency diesel generator sets in cubicle (enclosure) design for 6600 V are intended for standby power supply of large buildings and facilities fed at medium voltage: hospitals, public institutions, banks, data centres and power stations. The sets comply with the requirements of the Japanese Fire Service Act for cubicle own-power stations, hold a certificate of the Japan engine generator association (NEGA), and are built to JIS, JEC and JEM standards and technical rules for electrical installations. All equipment needed for operation (diesel engine, generator, control system and storage batteries) is placed inside the cubicle. Therefore no labour-intensive wiring and piping installation or special foundation is required, the installation occupies a very small area, and a separate generator room is not needed: the set can be placed in a corner of the machine hall or on the roof, including in an existing building where it is difficult to allocate a non-combustible room. An optimized combination of engine and generator provides fast start-up, within 40 or 10 seconds after loss of mains supply; microprocessor control ensures reliable start-up, stable operation and a fully automatic mode. The medium-voltage range consists of four-pole generators at 6600 V with power from 300/320 to 1000/1250 kVA (for 50/60 Hz); example: model KT-700CLH 6600 V 625/700 kVA. The enclosure is designed for indoor or outdoor installation. Operating conditions: ambient temperature from −5 to +40 °C, relative humidity up to 85%, altitude up to 300 m above sea level for models ZT-66CK…KT-1250CKH. Batteries are lead-acid with a regulating valve (REH). Finish: Munsell 5Y7/1, semi-gloss. Noise options are standard, low-noise (about 85 dB(A) at 1 m) and super-low-noise (about 75 dB(A) at 1 m). The sets serve as an emergency standby power source; the company also supplies gas-turbine and steam-turbine generator sets for continuous operation (no published specifications).
Technical specifications
| Voltage | 6600 V |
|---|---|
| Power | 300/320 – 1000/1250 kVA (50/60 Hz) |
| Generator poles | 4 |
| Example | KT-700CLH 6600 V 625/700 kVA |
| Start-up | within 40 or 10 s after loss of mains, fully automatic |
| Design | cubicle (enclosure) for indoor or outdoor installation |
| Conditions | −5…+40 °C, ≤85% relative humidity, altitude ≤300 m |
| Noise | standard; ≈85 dB(A) at 1 m; ≈75 dB(A) at 1 m |
| Standards | JIS, JEC, JEM, Japanese Fire Service Act; NEGA certificate |