Hydro-generators for small hydropower plants up to 10 MVA, 380 V–13.8 kV
Generators for hydropower, from micro hydro plants to stations with a capacity of several megawatts, are produced by the manufacturer’s division.
- Synchronous
- up to 10 MVA, 380–13,800 V, up to 32 poles
- Asynchronous
- up to 700 kW, slow-speed
- D2G (permanent magnets)
- up to 500 kW, no inverter, constant rotational speed
- Rotational speed
- 187–1800 rpm
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Generators for hydropower, from micro hydro plants to stations with a capacity of several megawatts, are produced by the manufacturer’s division. The range includes synchronous generators up to 10 MVA at 380–13,800 V with up to 32 poles, slow-speed asynchronous generators up to 700 kW and D2G permanent-magnet generators up to 500 kW, which operate at constant rotational speed without an inverter. The rotational speed from 187 to 1800 rpm is selected individually for the turbine and the drive system. According to the manufacturer’s brochure, typical combinations are: at 187–600 rpm, 90–700 at 12–24 poles; at 187–1800 rpm, 485–5600 at 4–32 poles; at 300–429 rpm, 110–330 at 14–22 poles (the brochure gives the graphs in MW for 60 Hz and MVA for 50 Hz). Generators are designed for a specific project: at the customer’s request the cooling method (air or water, with a separate cooling circuit), bearings (ball, roller, sliding, insulated, for vertical and high axial loads), degree of protection, mounting arrangement (horizontal or vertical) and couplings can be changed. For harsh conditions, closed bedplates, protection against corrosion and humidity, and additional ProtexPlus coatings are provided. Insulation is class H with vacuum-pressure impregnation (VPI); medium- and high-voltage machines use the HVi insulation system, designed for voltages up to 15.75 kV. Regulation is by digital regulators with site-specific settings, built-in protections, an APO function for eight alarm parameters, load control and fault recording. Bearing and winding temperature sensors, vibration sensors, heaters, current transformers and over-excitation protection are available. According to the manufacturer, the company has more than 70 years of experience in manufacturing hydro-generators, and many of its machines operate at stations in Europe and beyond. The generators are built to international standards and can be adapted to specific environmental and operating requirements. Applications: small and micro hydropower plants, diversion and run-of-river stations, refurbishment and replacement of generators at existing stations, installations on water conduits and in water-supply systems. Separately, the manufacturer produces permanent-magnet generators of about 100 kW for wind turbines.
Technical specifications
| Synchronous | up to 10 MVA, 380–13,800 V, up to 32 poles |
|---|---|
| Asynchronous | up to 700 kW, slow-speed |
| D2G (permanent magnets) | up to 500 kW, no inverter, constant rotational speed |
| Rotational speed | 187–1800 rpm |
| Typical ranges | 187–600 rpm: 90–700, 12–24 poles; 187–1800 rpm: 485–5600, 4–32 poles; 300–429 rpm: 110–330, 14–22 poles |
| Cooling | air or water |
| Mounting | horizontal or vertical |
| Insulation | class H, VPI; ProtexPlus option |
| Bearings | ball, roller, sliding, for vertical and high axial loads |
Request a price and lead time
Hydro-generators for small hydropower plants up to 10 MVA, 380 V–13.8 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Similar equipment from other manufacturers