HSJ / HSV / HSM — salient-pole synchronous hydro generators up to 50 MVA, 15 kV, up to 50 poles
HSJ, HSV and HSM are series of high-voltage synchronous hydro generators with a salient-pole rotor up to 50 MVA at voltage up to 15 kV. They are installed at new and refurbished hydropower plants with Francis, Kaplan and Pelton turbines. The series differ in cooling scheme and degree of protection.
- Power
- up to 50 MVA (small hydro from 100 kVA)
- Voltage
- up to 15 kV (range 400 V – 15 kV)
- Number of poles
- up to 50 (usually 4–50)
- Frequency
- 50 and 60 Hz
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
For hydro units the manufacturer mostly builds salient-pole machines with low speed and a large number of poles. Poles are fixed with bolts or a dovetail joint, and in small machines the rotor lamination is laser-cut in one piece. The generator is designed for increased runaway speed and additional radial and axial loads. For small and medium hydropower plants outputs start from 100 kVA and reach 50 000 kVA. The design is horizontal or vertical, with usually 4 to 50 poles, voltage from 400 V to 15 kV, frequency 50 or 60 Hz.
HSJ has open cooling IC01 and degree of protection IP23, and is made horizontal, vertical (IM8025) or for installation in a shaft (IM8425), up to 50 MVA. HSV, self-ventilated with ducted air supply IC31, has protection IP54 and output up to 25 MVA with 10 poles. HSM is enclosed, with air-to-water cooling IC81W/IC86W, IP55, frame size up to 2000–2600, up to 50 MVA. Stator insulation is class F or H, rotor F. Excitation is brushless as standard, from an AC exciter with PMG and AVR, static on request.
The design can be supplemented with a flywheel. Bearing assemblies are made with flanged end shields for machines under 100 t, and for heavier ones, under 200 t, with pedestal bearings or spider supports. With the generators the manufacturer supplies digital voltage regulators and control cabinets with protection and synchronization, and for pumped storage plants also frequency converters.
Supply examples show the range of the series well. An HSM generator for a hydropower plant with a Pelton turbine is rated 11 kV, 22 470 kVA, 500 rpm. An HSJ for a plant with a Kaplan turbine is rated 6.3 kV, 16 500 kVA, 300 rpm, and was supplied for refurbishment. Another generator for a Pelton turbine is rated 10.5 kV, 15 000 kVA, 1000 rpm. The manufacturer's machines operate, among others, at the Rothleiten, Gries, Tumpen, Koksay and Giresun hydropower plants.
The series suit as an alternative to hydro generators СГ, ВГС and ГС of small and medium output. For selection, state the output, voltage, speed and turbine type, vertical or horizontal design, runaway speed, axial loads, and the cooling conditions in the machine hall.
Technical specifications
| Power | up to 50 MVA (small hydro from 100 kVA) |
|---|---|
| Voltage | up to 15 kV (range 400 V – 15 kV) |
| Number of poles | up to 50 (usually 4–50) |
| Frequency | 50 and 60 Hz |
| Rotor | salient-pole (poles bolted or dovetail) |
| Excitation | brushless (standard) or static |
| HSJ | IC01, IP23, vertical (IM8025/IM8425, including in a shaft) and horizontal, up to 50 MVA |
| HSV | self-ventilated with ducted air supply IC31, up to IP54, up to 25 MVA |
| HSM | IC81W/IC86W, IP55, up to 50 MVA, frame size up to 2600 |
| Insulation | stator F or H, rotor F |
| Options | flywheel, axial load capacity, pedestal bearings < 200 t |
Request a price and lead time
HSJ / HSV / HSM — salient-pole synchronous hydro generators up to 50 MVA, 15 kV, up to 50 poles. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8501 63 00 00 8501 64 00 00 |
|---|---|
| HS, 6 digits | 8501 63 8501 64 |
| CN (EU) | 8501 63 00 8501 64 00 |
| HTSUS (USA) | 8501 63 00 00 8501 64 00 00 |
| China customs tariff | 8501 63 00 00 8501 64 10 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What output and voltage do the HSJ, HSV and HSM hydro generators have?
From 100 kVA to 50 MVA, voltage from 400 V to 15 kV. Frequency is 50 or 60 Hz.
How many poles can these generators have?
Usually from 4 to 50 poles. HSV with 10 poles is made up to 25 MVA.
Which turbines and plants are the series intended for?
Hydropower plants with Francis, Kaplan and Pelton turbines, both new and refurbished. For pumped storage plants the manufacturer also supplies frequency converters.
Similar equipment from other manufacturers