International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

HSJ / HSV / HSM — salient-pole synchronous hydro generators up to 50 MVA, 15 kV, up to 50 poles

HSJ, HSV and HSM are series of high-voltage synchronous hydro generators with a salient-pole rotor up to 50 MVA at voltage up to 15 kV. They are installed at new and refurbished hydropower plants with Francis, Kaplan and Pelton turbines. The series differ in cooling scheme and degree of protection.

Power
up to 50 MVA (small hydro from 100 kVA)
Voltage
up to 15 kV (range 400 V – 15 kV)
Number of poles
up to 50 (usually 4–50)
Frequency
50 and 60 Hz

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

For hydro units the manufacturer mostly builds salient-pole machines with low speed and a large number of poles. Poles are fixed with bolts or a dovetail joint, and in small machines the rotor lamination is laser-cut in one piece. The generator is designed for increased runaway speed and additional radial and axial loads. For small and medium hydropower plants outputs start from 100 kVA and reach 50 000 kVA. The design is horizontal or vertical, with usually 4 to 50 poles, voltage from 400 V to 15 kV, frequency 50 or 60 Hz.

HSJ has open cooling IC01 and degree of protection IP23, and is made horizontal, vertical (IM8025) or for installation in a shaft (IM8425), up to 50 MVA. HSV, self-ventilated with ducted air supply IC31, has protection IP54 and output up to 25 MVA with 10 poles. HSM is enclosed, with air-to-water cooling IC81W/IC86W, IP55, frame size up to 2000–2600, up to 50 MVA. Stator insulation is class F or H, rotor F. Excitation is brushless as standard, from an AC exciter with PMG and AVR, static on request.

The design can be supplemented with a flywheel. Bearing assemblies are made with flanged end shields for machines under 100 t, and for heavier ones, under 200 t, with pedestal bearings or spider supports. With the generators the manufacturer supplies digital voltage regulators and control cabinets with protection and synchronization, and for pumped storage plants also frequency converters.

Supply examples show the range of the series well. An HSM generator for a hydropower plant with a Pelton turbine is rated 11 kV, 22 470 kVA, 500 rpm. An HSJ for a plant with a Kaplan turbine is rated 6.3 kV, 16 500 kVA, 300 rpm, and was supplied for refurbishment. Another generator for a Pelton turbine is rated 10.5 kV, 15 000 kVA, 1000 rpm. The manufacturer's machines operate, among others, at the Rothleiten, Gries, Tumpen, Koksay and Giresun hydropower plants.

The series suit as an alternative to hydro generators СГ, ВГС and ГС of small and medium output. For selection, state the output, voltage, speed and turbine type, vertical or horizontal design, runaway speed, axial loads, and the cooling conditions in the machine hall.

Technical specifications

Powerup to 50 MVA (small hydro from 100 kVA)
Voltageup to 15 kV (range 400 V – 15 kV)
Number of polesup to 50 (usually 4–50)
Frequency50 and 60 Hz
Rotorsalient-pole (poles bolted or dovetail)
Excitationbrushless (standard) or static
HSJIC01, IP23, vertical (IM8025/IM8425, including in a shaft) and horizontal, up to 50 MVA
HSVself-ventilated with ducted air supply IC31, up to IP54, up to 25 MVA
HSMIC81W/IC86W, IP55, up to 50 MVA, frame size up to 2600
Insulationstator F or H, rotor F
Optionsflywheel, axial load capacity, pedestal bearings < 200 t

Request a price and lead time

HSJ / HSV / HSM — salient-pole synchronous hydro generators up to 50 MVA, 15 kV, up to 50 poles. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8501 63 00 00
8501 64 00 00
HS, 6 digits8501 63
8501 64
CN (EU)8501 63 00
8501 64 00
HTSUS (USA)8501 63 00 00
8501 64 00 00
China customs tariff8501 63 00 00
8501 64 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What output and voltage do the HSJ, HSV and HSM hydro generators have?

From 100 kVA to 50 MVA, voltage from 400 V to 15 kV. Frequency is 50 or 60 Hz.

How many poles can these generators have?

Usually from 4 to 50 poles. HSV with 10 poles is made up to 25 MVA.

Which turbines and plants are the series intended for?

Hydropower plants with Francis, Kaplan and Pelton turbines, both new and refurbished. For pumped storage plants the manufacturer also supplies frequency converters.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides