TRM-20 winding resistance meter, 25 A DC, 1 µΩ to 2000 Ω

The TRM-20 measures the DC resistance of transformer and electrical machine windings with currents from 1 to 25 A, over a range of 1 µΩ to 2000 Ω. It offers two measuring channels, automatic discharge, demagnetisation after testing and an on-load tap changer test.

Type
portable winding resistance meter for transformers
Resistance range
1 µΩ to 2000 Ω
Accuracy
1–19999 µΩ ±0.5%; 20–999 mΩ ±1%; 1–2000 Ω ±1.5% (±1 count)
Test current
1–25 A in 1 A steps

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TRM-20 measures two windings at the same time through its two input channels, for example the primary and secondary winding of a transformer. For large transformers, a 60 V DC charging source brings the current to a steady level quickly, and the voltage stays below 18 V during measurement. Test current is set from 1 to 25 A in 1 A steps.

The meter is used for DC resistance measurement of power transformer windings, rotating machine windings and any inductive object. Its range down to 1 µΩ also allows it to act as a micro-ohmmeter, for instance to measure the contact resistance of extra high voltage circuit breakers. This is the third generation of winding resistance meters in this line. For higher currents, the TRM-40 covers 1 to 40 A with an upper limit of 500 Ω.

Accuracy is ±0.5% of reading plus one count from 1 to 19999 µΩ, ±1% from 20 to 999 mΩ, and ±1.5% from 1 to 2000 Ω. After each measurement, automatic discharge removes stored energy from the winding to protect personnel, while the demagnetisation function clears residual magnetism from the core without a separate manual step. The OLTC test mode records the dynamic characteristics of the tap changer.

Memory holds 256 static reports of up to 111 measurements each and 120 dynamic reports, and up to 999 reports can be saved to an external USB drive. Results are printed by a built-in 2.5 inch thermal printer, and the backlit LCD stays readable in direct sunlight. PC communication runs over RS-232C, USB or Bluetooth.

The meter runs from 100-240 V AC at 50/60 Hz. Operating temperature is -10 to 50 °C, storage -30 to 70 °C, humidity up to 90% at 40 °C without condensation, and altitude up to 2000 m. The design complies with CAN/CSA C22.2 and UL 61010A-1. Before testing, the transformer must be disconnected and fully isolated, and leads must stay connected during measurement. The kit contains a current cable set, two sets of potential cables of 15.24 m each, a 4.57 m OLTC control cable, an earth cable, a power cable, and RS-232C and USB cables of 1.83 m each. A transport case is available as an option.

Technical specifications

Typeportable winding resistance meter for transformers
Resistance range1 µΩ to 2000 Ω
Accuracy1–19999 µΩ ±0.5%; 20–999 mΩ ±1%; 1–2000 Ω ±1.5% (±1 count)
Test current1–25 A in 1 A steps
Voltage60 V DC charging, up to 18 V DC during measurement
Channelstwo static channels
Displaybacklit LCD, 64 × 128 dots
Printerbuilt-in thermal printer, 2.5 inch
Internal memory256 static reports of up to 111 measurements, 120 dynamic
External memoryup to 999 reports on a USB drive
InterfacesRS-232C, USB, Bluetooth
Supply100-240 V AC, 50/60 Hz
Operating temperature-10 to 50 °C
Storage temperature-30 to 70 °C
Humidityup to 90% at 40 °C without condensation
SafetyCAN/CSA C22.2 and UL 61010A-1
Dimensions53 × 43 × 24 cm
Weight15.4 kg

Part numbers

Show all part numbers (9)

9007-UC, 8000-0005, 8000-0006, 8000-0015, 8000-0016, 8000-0071, 8000-0083, 8000-0087, 8000-0148

Request a price and lead time

TRM-20 winding resistance meter, 25 A DC, 1 µΩ to 2000 Ω. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Can two windings be measured at the same time?

Yes, the two input channels measure the resistance of two windings, such as primary and secondary, with a single current connection.

Can the instrument check the contacts of circuit breakers?

Yes, the range from 1 µΩ allows the TRM-20 to be used as a micro-ohmmeter for the contacts of extra high voltage circuit breakers.

Does the transformer need demagnetising after measurement?

The instrument demagnetises the core automatically after the test, so no separate manual operation is needed.