TOVT Toroidal Variable Transformers, 10-300 kVA, 120-600 V Input
TOVT toroidal variable transformers give a smoothly adjustable output from an input of 120 to 600 V AC. Output is set as a percentage of input voltage, 0-100% or 0-117%, and single-phase and three-phase versions with manual or motor drive are available.
- Power
- 10-300 kVA
- Input voltage
- 120 to 600 V AC
- Output voltage
- 0-100% or 0-117% of input
- Output above line
- up to 17%
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
TOVT units serve as multi-purpose adjustable power sources, including in test set-ups and for voltage regulation. They are simple autotransformers with a doughnut-shaped core and high efficiency. Copper windings wrap around the toroidal core to form a toroidal coil. The outer surface of the winding is left bare for the carbon brush, which travels along it on a pivoting arm known as the swinger. The arm is mounted at the centre of the toroid and turns through up to 318 degrees, and the output voltage changes in a straight line with the angle of rotation.
Several units can be stacked on a common shaft and connected in series or in parallel. Series connection doubles the line voltage and so raises current and power, hence the range from 10 to 300 kVA. Parallel assemblies use current chokes, and each unit has its own cooling fan. Overload capacity is 250% for 2 minutes, and output can exceed line voltage by 17%. The wiring diagram is on the terminal panel.
Smaller assemblies can have a manual drive for fine voltage control. Automatic control and larger ratings need a motor drive, which uses a chain transmission. Changing the sprockets sets the speed of the arm relative to the motor speed, and so the regulation time. The standard rise time is 60 seconds for AC drives and 15 seconds for DC drives, and the DC motor gives a variable rise rate. Limit switches at the top and bottom of the winding stop the regulator from travelling beyond its stroke.
Drive codes in the model designation are as follows. M is a manual drive, available only up to and including the -S6 models. N runs from 120 VAC, single phase, and O from 230 VAC, single phase, both with a 60-second rise time. P runs from 230 VAC, three phase, with a 15-second rise time at 60 Hz, and Q from 90 VDC with a 15-second rise time.
Each unit has lifting points for a crane. Enclosures are available with IP21 protection to IEC 529, which guards against solid objects 12 mm in diameter and against dripping water. The cabinet is made of heavy plate steel with a polyurethane coating and stands on steel skids for forklift handling. Precise assembly extends service life and reduces maintenance.
Technical specifications
| Power | 10-300 kVA |
|---|---|
| Input voltage | 120 to 600 V AC |
| Output voltage | 0-100% or 0-117% of input |
| Output above line | up to 17% |
| Overload | 250% for 2 minutes |
| Arm rotation | up to 318 degrees |
| Phases | single or three |
| Drive | manual or motor |
| Rise time (AC) | 60 seconds |
| Rise time (DC) | 15 seconds |
| Cooling | individual fans |
| Cabinet protection | IP21 (IEC 529), solid objects from 12 mm |
Part numbers
Show all part numbers (5)
M, N, O, P, Q
Request a price and lead time
TOVT Toroidal Variable Transformers, 10-300 kVA, 120-600 V Input. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the output be higher than the line voltage?
Yes. In the 0-117% version the output can exceed the line voltage by up to 17%. Connecting the transformers in series doubles the line voltage.
When is a motor drive needed?
The manual drive M is available only up to and including the -S6 models. For larger ratings and automatic control, the motor drives N, O, P or Q are used.
What overload can the transformer withstand?
It can carry an overload of 250% for 2 minutes.