International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TM1800-72D Test Stand for DC Traction Motors, Armature 0-1800 V

A no-load test set for DC traction motors, with separate supplies for the armature, the field winding and the impedance test circuit. The TM1800-72D delivers up to 1800 V to the armature and up to 2000 A to the field winding, with digital channels for speed, vibration and temperature.

Model
TM1800-72D
Supply
480 V AC, 160 A, three-phase, 60 Hz
Armature output
0-1800 V DC, 40 A
Field winding output
0-12 V DC, 2000 A

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TM1800-72D supplies a no-load test stand for high power DC traction motors. It is used in repair works for railway and urban electric transport, in rewinding shops and at test stations, where the armature, the field winding and the winding reactance are checked after repair.

All three independent sources sit in one industrial cabinet: an armature circuit of 0-1800 V DC at 40 A, a field winding source of 0-12 V at 2000 A, and an AC source of 0-50 V at 50 A for impedance testing. Each output has its own controls, measuring circuits and protection. Voltage is regulated across the whole range, with ripple below 5%. The unit runs from a 480 V AC three-phase supply at 160 A and 60 Hz, and other input voltages are made to order.

The measuring package covers the electrical and mechanical parameters of the motor. A non-contact tachometer reads 0-9999 rpm. The vibration channel has a four-position switch, four output sockets and two sensors on magnetic bases, reading 0-10.00 mil displacement or 0-0.3 in/sec velocity. Temperature is monitored by two type E or J thermocouples over 0-200.0 °C, and all readings are digital and shown on the operator panel.

Operator protection includes a main breaker and a control circuit breaker, both with indicators, an open security circuit interlock, an emergency stop mushroom button, a zero-start interlock, provision for external interlock and warning circuit, thermal overload protection on every regulator output, and transient protection on meters and relays. The cabinet is rugged steel with lifting eyes and removable side panels, cooling is by filtered forced air, and 15' (4.5 m) output cables are supplied.

Technical specifications

ModelTM1800-72D
Supply480 V AC, 160 A, three-phase, 60 Hz
Armature output0-1800 V DC, 40 A
Field winding output0-12 V DC, 2000 A
Impedance test output0-50 V AC, 50 A
Rippleless than 5%
Regulationless than 10%
Measurement accuracy±0.5% of range, plus or minus one least significant digit
Tachometernon-contact, 0-9999 rpm, accuracy +1 rpm
Vibration2 sensors on magnetic bases, 0-10.00 mil / 0-0.3 in/sec, ±1% of range
Temperature2 thermocouples, type E or J, 0-200.0 °C
Coolingforced air with filters
Output cables15' (4.5 m)
Calibrationtraceable to NIST/NRC

Request a price and lead time

TM1800-72D Test Stand for DC Traction Motors, Armature 0-1800 V. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which motors can be tested on this unit?

The TM1800-72D is designed for no-load testing of DC traction motors. For AC, synchronous and induction motors, and for shunt, compound and series wound motors, the range includes systems rated 100-200 kVA, 300-1000 kVA and 300-2500 kVA.

What supply does the unit need?

The standard supply is 480 V AC, 160 A, three-phase, 60 Hz. Other input voltages are made to order.

Which motor parameters are measured?

Speed is read by a non-contact tachometer from 0 to 9999 rpm, vibration by two sensors on magnetic bases, and temperature by two type E or J thermocouples up to 200.0 °C.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search