TD 1000 PLUS Dual-Output Relay Tester for Differential Protection

The TD 1000 PLUS checks protective relays during commissioning. Unlike the T 1000 PLUS, it has two current outputs, so besides the pick-up current it records the characteristic curve of a differential relay.

Type
relay test set for secondary injection with two current outputs
Main AC current output
up to 250 A
AC voltage
up to 250 V
DC voltage
up to 300 V

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The unit covers distribution protection and smart grid protection, single-phase relays, relays with high secondary burdens, and converters. Its second current source operates together with the main one, so both arms of a differential relay receive currents at the same time and the operating characteristic can be recorded. The manufacturer also lists tests of older railway network relays and generator protection.

The main output delivers alternating current up to 250 A, alternating voltage up to 250 V and direct voltage up to 300 V. The frequency generator is adjustable from 15 to 550 Hz, and both the current and voltage outputs have a phase shifter. The auxiliary AC voltage source reaches 260 V, the auxiliary DC source reaches 240 V, and the battery simulator works in the range from 20 to 260 V DC. Current and voltage generators can be used interchangeably.

The set has a large graphic display, an oscilloscope function for current and voltage, and a USB interface. Several TD 1000 PLUS units can be synchronised with one another for joint work. It runs from a 230 V ± 15 % or 120 V ± 15 % supply at 50-60 Hz, drawing at most 5 A, and measures 380 × 300 × 240 mm and weighs 19 kg.

The operating range is 0 to 50 °C, storage runs from -20 to 70 °C, and humidity is 10 to 80 % without condensation. Protection is IP 2X to EN 60529. The set complies with Directives 2004/108/EC and 2006/95/EC and the safety standard CEI EN 61010-1. The 15 Hz version offers the full range and higher power at 15 Hz, with 25 VA on all ranges, but it has no auxiliary DC voltage source and weighs 21 kg.

Technical specifications

Typerelay test set for secondary injection with two current outputs
Main AC current outputup to 250 A
AC voltageup to 250 V
DC voltageup to 300 V
Frequency source15 to 550 Hz
Auxiliary AC voltageup to 260 V
Auxiliary DC voltageup to 240 V
Battery simulator20 to 260 V DC
Power supply230 V ± 15 % or 120 V ± 15 %, 50-60 Hz
Maximum supply current5 A
Dimensions380 × 300 × 240 mm
Weight19 kg; 21 kg for the 15 Hz version
Operating temperature0 to 50 °C
Storage temperature-20 to 70 °C
Relative humidity10–80 % without condensation
Protection degreeIP 2X

Part numbers

Show all part numbers (3)

94093, 93093, 96093

Request a price and lead time

TD 1000 PLUS Dual-Output Relay Tester for Differential Protection. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the TD 1000 PLUS differ from the T 1000 PLUS?

The TD 1000 PLUS has two current outputs, so besides the pick-up current it records the characteristic curve of a differential relay.

What does the 15 Hz version offer?

The full range and 25 VA on all ranges at 15 Hz, but without an auxiliary DC voltage source.

Can several units be combined?

Yes. Several TD 1000 PLUS units can be synchronised with one another for joint testing.