STS 4000 Multifunction Test System for Current, Voltage and Power Transformers

The STS 4000 carries out primary tests on current transformers, voltage transformers, power transformers and earthing devices during substation commissioning and maintenance. Primary injection reaches 800 A, and with the BUX 5000 booster the rated figures are up to 5000 A and 7000 A.

Test objects
current transformers, voltage transformers, power transformers, earthing devices
Primary injection current
800 A; 5000 A / 7000 A with BUX 5000
High-voltage AC output
2000 V AC
Low-voltage AC output
140 V or 70 V AC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The STS 4000 is a multifunction test system for substation commissioning and maintenance. It tests current transformers, voltage transformers, power transformers and earthing devices, and it runs each test from stored test plans. Results are processed by the PADS software, which produces a condition assessment and a test report.

For current transformers the system measures the turns ratio in voltage mode, polarity, secondary burden, ALF and ISF, the magnetising curve and the knee-point voltage, as well as winding resistance and burden, and it carries out dielectric tests. It also checks Rogowski coils, low-power transformers and transformers with IEC 61850-9 output. Voltage transformers are measured for turns ratio, polarity and secondary burden. For power transformers the system covers turns ratio, vector group, winding resistance, dynamic resistance of the OLTC, magnetising and no-load current, short-circuit voltage and leakage reactance.

The main generator provides an AC high-voltage output up to 2000 V AC for dielectric tests, low-voltage outputs of 140 V or 70 V AC and 65 V DC at 6 A DC, and an output frequency adjustable from 15 to 500 Hz with a resolution of 10 mHz. The measuring inputs accept current up to 10 A AC or DC, and voltages of 300 V AC, 3 V AC and 10 V DC. The timer resolves 1 ms, and the phase angle error is below 0.1°.

The functions are extended by optional modules. The BUX 2000, BUX 3000 and BUX 5000 boosters supply primary injection current, the TD 5000 measures tan delta and capacitance at voltages up to 12 kV, including on generators and motors, and the STCS and STCS PLUS switch the transformer circuits automatically. The STDE demagnetises transformer cores.

Control is local from a 640 by 480 colour TFT display or remotely from a computer over USB or Ethernet. Memory holds up to 64 test plans and more than 1,000 test results. The unit runs from 100 to 230 V with a tolerance of ±15%, draws up to 16 A, and measures 450 × 400 × 230 mm. It works at -10 to 55 °C, with humidity of 5 to 95% without condensation, up to 2000 m altitude, and carries IP 2X protection to IEC 60529, with IP 4X for the high-voltage output.

Technical specifications

Test objectscurrent transformers, voltage transformers, power transformers, earthing devices
Primary injection current800 A; 5000 A / 7000 A with BUX 5000
High-voltage AC output2000 V AC
Low-voltage AC output140 V or 70 V AC
Low-voltage DC output6 A, 65 V, 360 W
Output frequency15 to 500 Hz, 10 mHz resolution
Tan delta with TD 5000maximum 12 kV
Measuring inputs10 A AC or DC; 300 V AC; 3 V AC; 10 V DC
Internal measurement accuracybelow 0.05% of reading, below 0.05% of range
Phase angle errorbelow 0.1°
Timer1 ms resolution
DisplayTFT, 640 x 480, 132 x 99 mm
InterfacesUSB, Ethernet, IEC 61850-9-2
Memoryup to 64 test plans, more than 1,000 results
Mains supply100 to 230 V ±15%, up to 16 A
Dimensions450 x 400 x 230 mm
Operating temperature-10 to 55 °C
Humidity5 to 95%, non-condensing
Protection classIP 2X, IP 4X for the high-voltage output

Request a price and lead time

STS 4000 Multifunction Test System for Current, Voltage and Power Transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the maximum primary injection current?

The built-in output reaches 800 A, and with the optional BUX 5000 booster the rated figures are up to 5000 A and 7000 A.

Can tan delta and capacitance be measured?

Yes, with the optional TD 5000 module at voltages up to 12 kV, including on generators and motors.

Does the system support transformers with digital output?

Yes. The system works with the IEC 61850-9-2 protocol and tests current and voltage transformers that have IEC 61850-9 output.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides