Spark P3 Universal Partial Discharge and EMI Analyser
Spark P3 detects signs of insulation deterioration in high-voltage equipment from partial discharge and electromagnetic interference signals between 9 kHz and 2 GHz. It works with sensors for rotating machines, transformers, switchgear and cables.
- Partial discharge and EMI range
- 9 kHz up to 2 GHz
- Acoustic signals and reference voltage
- DC to 500k Hz
- Detector type
- software-defined radio receiver
- Modes
- Wizard Mode, Expert Mode
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The analyser is used to diagnose insulation systems in high-voltage equipment, including rotating machines, power and instrument transformers, gas and air insulated switchgear, cables and cable accessories. Its detector is built as a software-defined radio receiver. It accepts partial discharge and electromagnetic interference signals from sensors spanning 9 kHz up to 2 GHz, and it also takes acoustic signals and a reference voltage in the DC to 500k Hz range.
Rotating machines are measured with coupling capacitors and HFCT sensors, power transformers with HFCT sensors, UHF antennas and acoustic microphones, and instrument transformers with HFCT sensors. Switchgear is checked with TEV sensors, UHF antennas, HFCT sensors, acoustic sensors and sensors mounted on insulating spacers and inspection windows. Cables are tested with HFCT, UHF and acoustic sensors.
The PDDC-17 and PDDC-24 units carry partial discharge signals from rotating machines, with more than 30 MHz of bandwidth into a 50 Ohm matching resistance. They have a built-in measuring impedance to IEC 60270 and a voltage signal for phase-resolved measurements, and the PDDC-24 also includes a high-voltage fuse. The UHF Drain Valve Sensor fits transformer drain valves of DN50 or DN80, while the UHF PD Plate Sensor suits transformers without free flanges and can be fitted during manufacture. The split HFCT-300 measures load or reactive currents of 50/60 Hz up to 300 A, and the HFCT-100 (mini) has three channels for a set of bushings. The 5 inch internal diameter HFCT has a transfer impedance of 13dBΩ (+2dBΩ) from 1MHz to 100MHz and handles line currents up to 350 amperes from DC to 400Hz. For gas insulated switchgear there is a UHF Spacer Sensor and a capacitive TEV-Probe.
Wizard Mode limits the functions to those needed and guides an inexperienced operator through the measurement procedure, while Expert Mode lets the user configure measurements freely. Test plans are predefined or can be set up, and data collection is automatic. The software displays spectrum, time and phase-resolved views in the HF and VHF ranges.
The analyser runs on battery and is used as a benchtop unit in the laboratory or in a protected case on site, and an adapter mounts it in a 19 inch rack. Its low weight allows it to be carried on aircraft, both in the cabin and in checked baggage.
Technical specifications
| Partial discharge and EMI range | 9 kHz up to 2 GHz |
|---|---|
| Acoustic signals and reference voltage | DC to 500k Hz |
| Detector type | software-defined radio receiver |
| Modes | Wizard Mode, Expert Mode |
| Analysis | spectrum, time and phase-resolved views in HF and VHF |
| Form | benchtop or in a case, adapter for 19 inch rack |
| Power | battery |
| PDDC-17, PDDC-24 | over 30 MHz of bandwidth into 50 Ohm, IEC 60270 |
| HFCT-300 | reactive currents up to 300 A |
| HFCT 5 inch ID | 127mm internal diameter, 13dBΩ (+2dBΩ) transfer impedance, 1MHz to 100MHz, up to 350 A from DC to 400Hz |
| UHF sensors for transformers | Drain Valve Sensor DN50/DN80, PD Plate Sensor |
| Sensors for gas insulated switchgear | UHF Spacer Sensor, TEV-Probe |
Part numbers
Show all part numbers (10)
PDDC-17, PDDC-24, UHF Drain Valve Sensor DN50/DN80, UHF PD Plate Sensor, LDWS-T Sensor, HFCT-300 sensor, HFCT-100 (mini) sensor, HFCT 5 inch ID, UHF Spacer Sensor, TEV-Probe
Request a price and lead time
Spark P3 Universal Partial Discharge and EMI Analyser. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What frequency range does the Spark P3 cover?
Partial discharge and EMI signals are received from 9 kHz up to 2 GHz, and acoustic signals and the reference voltage from DC to 500k Hz.
Which sensors are needed for rotating machines?
PDDC-17 or PDDC-24 units with over 30 MHz of bandwidth into 50 Ohm and a measuring impedance to IEC 60270, together with HFCT sensors.
Can the analyser be mounted in a rack?
Yes. An adapter fits a 19 inch rack, and the unit also works on a benchtop or in a case on site.