RIV-3 Radio Influence Voltage Measurement System with 9 kHz Bandwidth

The RIV-3 gives radio influence voltage readings to NEMA 107-1987 and related standards, using a 9 kHz bandwidth with a centre frequency adjustable from 10 kHz to 10 MHz. Typical settings include transformer labs, partial discharge work, insulation checks on high-voltage plant, upkeep of rotating machines and electromagnetic interference diagnostics.

Type
radio influence voltage (RIV) measurement system
Bandwidth
9 kHz (ANSI C63.3-1996)
Centre frequency
10 kHz to 10 MHz
Display scale
0 to 2500 µV (at k=1)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The RIV-3 is an instrument for measuring radio influence voltage in line with NEMA 107-1987 and other relevant standards. Transformer laboratories use it for partial discharge work, while insulation diagnostics on high-voltage plant, upkeep of rotating machines on a condition basis and electromagnetic interference assessments also fall within its scope.

The measuring channel has a 9 kHz bandwidth and a centre frequency that can be set anywhere from 10 kHz to 10 MHz. Its display scale runs from 0 to 2500 µV at k=1, and the range is selected automatically. A separate reference channel covers 100 kHz to 2 MHz in 10 kHz steps and is used for calibration.

Calibration is carried out with the CAL3A calibrator, which produces frequencies from 600 kHz to 1350 kHz in 50 kHz steps and outputs between 10 µV and 10 mV in 1-2-5 steps. The desktop unit combines three measurement channels with a backlit LCD, and it communicates with a computer over USB at a fixed 57.6 bit/s.

A multiplexer compares the calibrator voltage applied to the input with the voltage at the measuring tap of that input and determines the k-factor automatically. The correction factor is stored separately for each channel. Its design references NEMA 107-1987 and ANSI C63.3-1996 together with DIN EN 55016-1-1, VDE 876 and ANSI 63-2-1996.

Technical specifications

Typeradio influence voltage (RIV) measurement system
Bandwidth9 kHz (ANSI C63.3-1996)
Centre frequency10 kHz to 10 MHz
Display scale0 to 2500 µV (at k=1)
Number of channels3
Displaybacklit LCD
Range selectionautomatic
Calibration reference channel100 kHz to 2 MHz (10 kHz steps)
InterfaceUSB, fixed 57.6 bit/s
CAL3A calibrator frequency600 kHz to 1350 kHz, 50 kHz steps
CAL3A calibrator output10 µV to 10 mV, 1-2-5 steps
StandardsANSI C63.3-1996, DIN EN 55016-1-1, VDE 876, ANSI 63-2-1996, NEMA 107-1987

Part numbers

Show all part numbers (1)

RIV-3

Request a price and lead time

RIV-3 Radio Influence Voltage Measurement System with 9 kHz Bandwidth. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which standards does the RIV-3 measure against?

Its reference list names NEMA 107-1987 along with DIN EN 55016-1-1, VDE 876 and ANSI 63-2-1996, and its 9 kHz bandwidth follows ANSI C63.3-1996.

How is the correction factor determined?

A multiplexer compares the calibrator voltage applied to the input with the voltage at the measuring tap and determines the k-factor automatically. The correction factor is stored separately for each channel.

What frequency range can be set?

The measuring channel centre frequency adjusts from 10 kHz to 10 MHz, while the reference channel covers 100 kHz to 2 MHz in 10 kHz steps.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides