4120-10 and 4160-5 DC hipot sets for field use, 40–200 kV
Portable DC high voltage test sets rated from 40 kV to 200 kV for insulation testing in the field. The high-voltage section sits in a sealed, earthed aluminium tank filled with oil, with a built-in discharge device and a shielded output lead.
- Output voltage
- 40–200 kV DC
- Circuit
- filtered voltage doubler
- High-voltage section
- sealed, earthed aluminium tank with oil
- Ripple voltage
- <2% RMS at full voltage
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Portable DC hipot sets from 40 to 200 kV are designed for precise insulation testing with direct voltage in the field. The frame is light and rugged and built for years of use on site. The large charging current, standard across the whole line, lets sizeable capacitive loads be charged quickly.
The high voltage is produced by a filtered voltage doubler designed specifically for high-voltage testing. All high-voltage parts sit inside a sealed, earthed aluminium tank filled with oil. After a test, an electromagnetic discharge switch quickly discharges the load, and a shielded high-voltage lead lets the operator connect the output to the object safely. Under full voltage the ripple remains below 2 % RMS.
The standard series has a supply circuit breaker with indicator, an external signal circuit for a flashing lamp, high voltage on and off buttons, manual voltage adjustment, a start interlock that blocks start-up from any non-zero setting and an external interlock. Overload protection is adjustable from 10 % to 110 % of rated current. Instruments and relays are protected against transients, and the set includes 3 ½-digit multi-range digital meters, an analogue charging current ammeter, a guard mode and thermal protection of the primary circuit of the high-voltage transformer.
B models have a 7-inch colour touch display, automatic or manual voltage control, a USB port for data logging, PC control over WiFi with separate software, automatic range selection for the full and return-lead currents, a lock for the return lead and a shielded measuring lead. The display shows memory voltmeters for breakdown and maximum voltage, duration and dwell timers, a programmable voltage rise rate in V/s, a current cut-off threshold and an insulation resistance calculation.
Operating conditions are 10 to 40 °C, indoors or outdoors in dry weather, with humidity up to 95 % without condensation and altitudes up to 1000 m. Optional extras include a positive-polarity output, cables of the required length, calibration data, earthing and discharge rods, a hand-held safety switch with a 10’ (3 m) cable, a foot switch with a 20’ (6 m) cable, a flashing lamp and a hand trolley for the 4120-10 and 4160-5 models. ISO17025 calibration is available on request.
Technical specifications
| Output voltage | 40–200 kV DC |
|---|---|
| Circuit | filtered voltage doubler |
| High-voltage section | sealed, earthed aluminium tank with oil |
| Ripple voltage | <2% RMS at full voltage |
| Discharge | built-in, electromagnetic switch |
| Overload protection | 10–110% of rated current |
| Standard series instruments | 3 ½-digit digital, analogue charging current ammeter |
| Display, B models | 7-inch colour touch screen |
| Interfaces, B models | USB, WiFi |
| Operating temperature | 10–40 °C |
| Relative humidity | <95% non-condensing |
| Altitude | <1000 m |
| Calibration | ISO17025 on request |
Part numbers
Show all part numbers (2)
4120-10, 4160-5
Request a price and lead time
4120-10 and 4160-5 DC hipot sets for field use, 40–200 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Is a positive-polarity output available?
Yes, a positive-polarity output is available as an option when ordering.
How is the test object discharged after the test?
A built-in discharge device with an electromagnetic switch discharges the load quickly, and discharge and earthing rods can be ordered as extras.
Does the set calculate insulation resistance?
Yes, B models calculate insulation resistance and store the breakdown voltage in the memory voltmeter.