Physical measurement module for electric motor test benches
The module adds vibration, temperature and rotational speed measurement to a motor test bench. It supports up to 6 accelerometers, up to 16 RTDs and up to 16 thermocouples, and its optical tachometer reads up to 9999 rpm.
- Velocity range (vibration)
- 0 to 0.3 in/sec
- Displacement range (vibration)
- 0 to 10.00 mil
- Vibration accuracy
- ±1% of full range, plus LSD
- Accelerometers
- 0 to 6
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The module connects to almost any motor test bench, adding physical measurements to the electrical ones for a more detailed analysis of the motor. It suits AC and DC machines, traction drives, synchronous and induction designs, as well as machines wound for shunt, compound or series excitation.
The configuration is chosen for each application, as the customer selects the number of RTDs, thermocouples and accelerometers. The module offers interfaces to various industrial controllers, sits in a separate desktop housing with a trolley included, has a safety circuit interlock, and runs from a standard 120 or 240 V mains supply.
Vibration is measured as acceleration, velocity and displacement. The velocity range is 0 to 0.3 in/sec and the displacement range is 0 to 10.00 mil, with accuracy of ±1% of range plus LSD. Up to six accelerometers can be fitted, and the package includes 10’ (3 m) BNC cables, sensors and magnetic mounts.
The temperature channels accept platinum, nickel and copper RTDs and J, T, E and N thermocouples, with type J as standard. The range is 0 to 200.0 °C (32.0 to 320.0 °F) with an accuracy of ±1°. Between zero and sixteen of each sensor type can be configured, in groups of four, and a 15’ (5 m) extension lead is available as an option.
Rotational speed is measured by an optical tachometer with a removable sensor that plugs into the input socket. The range is 0 to 9999 rpm with an accuracy of ±1 rpm. The housing measures 20” (508 mm) by 16” (407 mm) by 12” (305 mm) and weighs about 37 lbs (17 kg), so the module can be wheeled between the workstations of the test bench.
Technical specifications
| Velocity range (vibration) | 0 to 0.3 in/sec |
|---|---|
| Displacement range (vibration) | 0 to 10.00 mil |
| Vibration accuracy | ±1% of full range, plus LSD |
| Accelerometers | 0 to 6 |
| BNC cables | 10’ (3 m) |
| RTD materials | platinum, nickel, copper |
| Thermocouple types | J, T, E, N (type J as standard) |
| Temperature range | 0–200.0 °C (32.0–320.0 °F) |
| Temperature accuracy | ±1° |
| RTD quantity | 0–16 (in groups of 4) |
| Thermocouple quantity | 0–16 (in groups of 4) |
| Extension lead | 15’ (5 m), optional |
| Tachometer range | 0–9999 rpm |
| Tachometer accuracy | ±1 rpm |
| Dimensions | 20” (508 mm) x 16” (407 mm) x 12” (305 mm) |
| Weight | about 37 lbs (17 kg) |
| Power supply | 120 or 240 V |
Request a price and lead time
Physical measurement module for electric motor test benches. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
How many sensors can be connected to the module?
Up to six accelerometers, and up to 16 RTDs and 16 thermocouples, with RTDs and thermocouples chosen in groups of four.
Which thermocouple and RTD types are supported?
Thermocouple types J, T, E and N, with J as standard, and platinum, nickel or copper RTDs over a range of 0–200.0 °C.
What mains supply does the module use?
A standard 120 or 240 V supply.
Similar equipment from other manufacturers