PD3U partial discharge detector, spectrum analyser and RIV meter in one unit

The PD3U combines a spectrum analyser, a partial discharge detector and a RIV meter in one instrument. Its spectrum view lets operators pick a band with less interference, so PD can be measured against strong background noise in unscreened areas.

Type
spectrum analyser, PD detector and RIV meter
Centre frequency
10 kHz – 10 MHz, step 10 kHz
Bandwidth
9 kHz and 270 kHz
Number of channels
4 (MUX4)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The PD3U assesses the condition of insulation systems and supports quality control in manufacturing plants. It also handles routine testing of cables, switchgear, generators, GIS, motors, transformers, vacuum chambers and insulating materials. PD measurements follow IEC 60270-2000 and IEEE C57.12.90, while RIV readings follow NEMA and CISPR requirements.

Its built-in spectrum analyser is the main feature. The operator watches the frequency spectrum of a noisy PD signal and selects a band where interference is lower and the discharge pattern is clearer. The centre frequency is set from 10 kHz to 10 MHz in 10 kHz steps, and the bandwidth is either 9 kHz or 270 kHz.

The instrument has four modes. Spec mode shows the spectrum of the input signal with a sweep up to 10 MHz, and three spectral curves can be stored and compared. Scope mode displays the PD pattern against phase at a sync frequency from 10 to 500 Hz. Meter mode presents PD activity on an analogue style meter, in three charge modes in pC (FAST, NORM, IEC270) and in µV for RIV. HVM mode shows the high voltage waveform at the SYNC input and flags distortion, while its built-in meter reads peak, peak over root two and RMS on a 100 Vrms input range with 1 MΩ impedance.

In RIV mode the four channel unit works as a selective microvoltmeter with the CISPR weighting curve. With the CAL3B calibrator for NEMA 107 or the CAL3D for CISPR 18-2, the range runs from 400 kHz to 1900 kHz in 100 kHz steps, with levels from 10 µV to 10 mV into 300 Ω. Each RIV channel needs a CIT4M/v2u0/RIV quadrupole, which offers Ck from 600 pF to 2.5 nF, Imax of 800 mA, Cd of 2 µF at Umax of 100 Vrms, and switchable 150 Ω / 300 Ω impedance.

The package includes an MUX4 multiplexer, a built-in logarithmic preamplifier RPA6, and TTL gating with a manual or automatic threshold to suppress interference. The unit has a backlit LCD of 240 x 128 dots and a USB link of up to 921 kB. Software controls the instrument remotely and records three dimensional phase resolved PD patterns. A 19 inch, 3RU rack mounting kit is available as an option. The mains input runs from 100 to 240 VAC, 25 VA, at 50 and 60 Hz, and the weight is 3 kg, and the operating temperature is 10 to 40 °C.

Technical specifications

Typespectrum analyser, PD detector and RIV meter
Centre frequency10 kHz – 10 MHz, step 10 kHz
Bandwidth9 kHz and 270 kHz
Number of channels4 (MUX4)
Synchronisationinternal 50/60 Hz, external 10-500 Hz
RIV range with CAL3B/CAL3D400 kHz – 1900 kHz, step 100 kHz
High voltage measurementpeak, peak/√2, RMS; 100 Vrms, 1 MΩ
Reference voltage input100 MΩ / 200 pF, max. 120 V (rms), 10-500 Hz
PD signal inputAC, 50 Ω (without RPA)
Displaybacklit LCD, 240 x 128 dots
InterfaceUSB, up to 921 kB
Power supply100-240 VAC mains, 50/60 Hz, 25 VA
Operating temperature10 to 40 °C
Dimensions236 x 295 x 133 mm
Weight3 kg
StandardsIEEE C57.12.90, IEC 60270-2000, NEMA 107, CISPR 18-2

Part numbers

Show all part numbers (2)

CIT4M/v2u0/RIV, CAL3D and CAL3B

Request a price and lead time

PD3U partial discharge detector, spectrum analyser and RIV meter in one unit. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How can PD be measured in an unscreened test hall?

The built-in spectrum analyser shows the signal spectrum, and the operator moves the centre frequency, from 10 kHz to 10 MHz, into a band with less interference.

What is needed for RIV measurements?

A CIT4M/v2u0/RIV quadrupole for each channel, plus a CAL3B calibrator for NEMA 107 or a CAL3D for CISPR 18-2.

Can the instrument be fitted in a control desk?

Yes, an optional 19 inch rack mounting kit, 3RU high, is available.