PD2U partial discharge detector to IEC 60270 with LCD and high voltage measurement
The PD2U is a benchtop partial discharge detector for acceptance, control and routine insulation tests on low and high voltage equipment. It runs on its own with button control or under computer control.
- Type
- single channel partial discharge detector
- Compliance
- IEC 60270
- Power supply
- 100-240 VAC mains, 50/60 Hz
- Power consumption
- 25 VA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Partial discharge (PD) measurement is a non-destructive way to assess the condition of electrical insulation. The PD2U is used to evaluate insulation systems, to check quality in manufacturing plants, and to carry out routine tests on equipment in the field. Its results conform to IEC 60270.
The single channel unit has a button interface and a backlit LCD of 240 x 128 dots. It offers four display modes: a PD charge meter with adjustable needle sensitivity, a monochrome phase resolved PD pattern for characterising defects, an oscilloscope view with phase summed charge pulses over the applied voltage curve, and a high voltage trace showing Û, Û/√2 and Urms. Auto ranging and saving of the current settings are included.
Synchronisation is internal from the 50/60 Hz mains or external from 15 to 510 Hz. The reference voltage input is a BNC with 1 MΩ and 200 pF impedance, a 120 V rms maximum and a 20 to 510 Hz range. The PD input is AC coupled with 50 Ω impedance without RPA, a lower cut-off of 40, 80 or 100 kHz and an upper cut-off of 250, 600 or 800 kHz. A USB link of up to 921 kB connects the unit to a computer for screenshots or remote control.
The unit works with a set of preamplifiers covering the IEC 60270 band and ultrasonic frequencies up to the UHF range of 20 kHz to 2 GHz. A DSO board with 100M sampling turns the PD2U into a tool for locating PD in power cables by reflectometry, estimating the relative distance to a defect from a PD pulse and its reflections. The MUX4 option adds a four channel multiplexer for three phase plant such as power transformers, with each channel set up and calibrated separately.
Mains input covers 100 to 240 VAC, with a 50/60 Hz supply and 25 VA consumption. The housing measures 236 x 295 x 133 mm and weighs 3 kg. Operating conditions are 10 to 40 °C indoors or outdoors in dry weather, humidity below 95% non-condensing, and altitudes up to 1000 metres.
Technical specifications
| Type | single channel partial discharge detector |
|---|---|
| Compliance | IEC 60270 |
| Power supply | 100-240 VAC mains, 50/60 Hz |
| Power consumption | 25 VA |
| Display | backlit LCD, 240 x 128 dots |
| Synchronisation | internal 50/60 Hz, external 15-510 Hz |
| Reference voltage input | 1 MΩ / 200 pF, max. 120 V (rms), 20-510 Hz |
| PD signal input | AC, 50 Ω (without RPA) |
| Lower cut-off frequency | 40, 80 or 100 kHz |
| Upper cut-off frequency | 250, 600 or 800 kHz |
| Interface | USB, up to 921 kB |
| Options | 100M DSO board for PD location in cable; MUX4 multiplexer |
| Unit operating temperature | 10°C – 45°C |
| Ambient conditions | 10-40°C, humidity <95% non-condensing, altitude <1000 metres |
| Dimensions | 236 x 295 x 133 mm |
| Weight | 3 kg |
Request a price and lead time
PD2U partial discharge detector to IEC 60270 with LCD and high voltage measurement. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Can the PD2U be used without a computer?
Yes, it is a standalone unit with button control and an LCD. A USB computer link is needed only for screenshots or remote control.
How can three phase transformers be checked with a single connection?
The MUX4 option adds a four channel multiplexer, with each channel separately set up and calibrated.
Can the PD2U locate a defect along a cable?
With the 100M DSO board it uses reflectometry to show the relative distance to the PD source along the cable.
Similar equipment from other manufacturers