International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

MTS-R and MTS-R2 high power motor test systems, 300–2500 kVA, up to 50000 HP

MTS-R and MTS-R2 test systems for loaded and no-load testing of high power AC and DC motors. Configurations allow a 10000 HP motor to be tested at full load and a 50000 HP motor at no load.

Series rating
300–2500 kVA
Maximum output of configurations
up to 10000 kVA
Motors at full load
up to 10000 HP
Motors at no load
up to 50000 HP

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These high power systems are used by motor manufacturers, service repair workshops, industrial plants, energy companies and government establishments. They run loaded and no-load tests on AC and DC machines, covering traction, synchronous and induction designs as well as shunt, compound and series-wound types. Each system is engineered to the customer's brief, from the initial specification through to commissioning.

The configuration is chosen from several options. Systems may be AC, DC or AC/DC, fed from a medium or low voltage supply, and deliver an output power of up to 10000 kVA. The largest configurations can test a 10000 HP motor under full load and a 50000 HP motor unloaded. Control may be manual, extended or fully automated, with separate software, a database and report generation.

Precise voltage control is provided by a column-type variable transformer. It has no sliding contacts to wear out or stick, and no sensitive power electronics whose failure could damage the windings. The standard MTS-R series regulates voltage by tap. The R2 design regulates across its full range without interruption, so the motor does not slow down when the tap changes.

The measurement section monitors voltage, current, power, active energy in kWh, vibration, temperature and rotational speed. Each system includes all the controls, power sources, instruments and protective devices needed for the test. The cabinet is made from thick steel plate with removable panels, lifting eyes and forklift pockets, and it meets NEMA 1 for indoor installation.

The control panels are primed and finished in a gloss polyurethane paint, and the labels on the indicators are permanent. Manufacture follows ISO9001, and every system passes final tests before it ships. Supply includes commissioning work and operator training.

Technical specifications

Series rating300–2500 kVA
Maximum output of configurationsup to 10000 kVA
Motors at full loadup to 10000 HP
Motors at no loadup to 50000 HP
System typeAC, DC or AC/DC
Supplymedium or low voltage
Voltage regulatorcolumn-type variable transformer
R2 designuninterrupted regulation when changing taps
Measurementvoltage, current, power, kWh, vibration, temperature, rotational speed
Controlmanual, extended or fully automated
Cabinetsteel, NEMA 1, indoor
Quality systemISO9001
SeriesMTS-R, MTS-R2

Request a price and lead time

MTS-R and MTS-R2 high power motor test systems, 300–2500 kVA, up to 50000 HP. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

How does the MTS-R2 differ from the MTS-R?

The R2 design regulates voltage across its full range without interruption, so the motor does not slow down when the tap is changed.

What size motor can be tested under load?

A 10000 HP motor can be tested at full load and a 50000 HP motor at no load.

Which quantities does the system measure?

Voltage, current, power, active energy in kWh, vibration, temperature and rotational speed.