M7100 high-voltage asset analyser, test voltage 0.250 to 12 kV
The M7100 carries out off-line tests on high-voltage equipment during commissioning, diagnostics and planned maintenance. Each of its two high-voltage terminals serves for both supply and measurement, and a built-in low-voltage multi-frequency source delivers high current.
- High-voltage AC
- 0.250 to 12 kV RMS
- High-voltage frequency
- 15 to 500 Hz
- Maximum high-voltage current
- 300 mA
- High-voltage voltage error
- 0.5%
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The unit tests transformers, circuit breakers, cables, instrument transformers, surge arresters and rotating machines. One set performs several high-voltage tests that previously needed separate instruments. Figures published for it show a full test cycle falling from seven hours to one and a half, and a load of instruments and cables that once needed a lorry is replaced by one unit.
Each high-voltage terminal switches between source mode and measuring mode, since both functions are built into every terminal. Compared with a single-wire layout, this cuts the number of ladder climbs to two thirds of the usual count and makes terminal placement, where most mistakes happen, simpler. Measurements use a true four-terminal connection with points marked by colour or number. A dedicated protective switch and an emergency stop button add safety.
The high-voltage AC output delivers 0.250 to 12 kV RMS over 15 to 500 Hz, with a maximum current of 300 mA and a voltage error of 0.5%. The low-voltage source gives 25 to 250 V RMS AC or 1 to 175 V DC at 1 to 1000 Hz, with up to 25 A RMS AC and 35 A DC, and an error of 0.1%.
Supply is single-phase 90 to 264 V AC at 47 to 63 Hz, and the unit can run from a portable generator or inverter. Power draw is 4 kW with up to 20 A, and it works with class A and class B residual current devices. A built-in server supports remote diagnostics, and self-tests check every measuring circuit. Operating range is -20 to +50 °C, storage is -40 to +70 °C, humidity 5 to 95% non-condensing, and altitude up to 10000 ft.
The unit meets EN 61010-1:2001 for safety and FCC 47 CFR Part 15 Class A with EN 55011 for electromagnetic compatibility. Shock testing follows IEC 60068-2-27 at 15 g for 11 ms, and vibration per IEC 60068-2-6 covers 10 to 150 Hz at 2 g. Its cabinet measures 32.75 by 21 by 16.5 inches and weighs 175 lb, with the transport container built in. The cable kit weighs 124 lb, or 185 lb with its case. Control runs from a field laptop or tablet using software with templates for every type of high-voltage apparatus, and a transport trolley doubles as the field computer's workstation.
Technical specifications
| High-voltage AC | 0.250 to 12 kV RMS |
|---|---|
| High-voltage frequency | 15 to 500 Hz |
| Maximum high-voltage current | 300 mA |
| High-voltage voltage error | 0.5% |
| Low-voltage AC | 25 to 250 V RMS |
| Low-voltage DC | 1 to 175 V |
| Low-voltage frequency | 1 to 1000 Hz |
| Maximum low-voltage current | 25 A RMS (AC), 35 A (DC) |
| Low-voltage error | 0.1% |
| Power supply | 90 to 264 V AC, single-phase, 47 to 63 Hz |
| Power consumption | 4 kW, 20 A max. |
| Operating temperature | -20 to +50 °C |
| Storage temperature | -40 to +70 °C |
| Relative humidity | 5 to 95%, non-condensing |
| Working altitude | below 10000 ft above sea level |
| Dimensions | 32.75 by 21 by 16.5 inches |
| Weight | 175 lb |
| Safety | EN 61010-1:2001 |
Request a price and lead time
M7100 high-voltage asset analyser, test voltage 0.250 to 12 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which equipment can the M7100 test?
Transformers, circuit breakers, cables, instrument transformers, surge arresters and rotating machines. The control software has test templates for each type of apparatus.
What are the parameters of the low-voltage source?
AC voltage of 25 to 250 V RMS or DC voltage of 1 to 175 V, at 1 to 1000 Hz, with up to 25 A RMS AC and 35 A DC at a 0.1% error.
Can the M7100 be powered from a generator?
Yes. The 90 to 264 V, 47 to 63 Hz input works with a portable generator or inverter. Consumption is up to 4 kW at up to 20 A.