IC injection capacitors free of partial discharge, 100 to 500 kV, 100 pF, for calibrating PD measurements

IC injection capacitors introduce a known partial discharge pulse into a system that is energised. The range covers rated voltages from 100 to 500 kV at 100 pF.

Purpose
introducing a known PD pulse into an energised system
Capacitance
100 pF (150 pF also offered for older detectors)
IC100-.01
100 kV, 100 pF, 50 to 400 Hz, on a base
IC200-.01
200 kV, 100 pF, 50 to 60 Hz, on casters with a base

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

IC injection capacitors are used when measuring partial discharge (PD) in high voltage test circuits. A pulse of known charge is passed through the capacitor into the test circuit while the object is already energised. This checks and calibrates the measuring path under real test conditions. The capacitor has no partial discharge of its own, so it does not distort the measurement.

Operation requires a CAL1C PD calibrator. In a multi-channel PD measurement system, each channel needs its own capacitor. In the calibration circuit the calibrator produces a pulse of set charge, and the capacitor passes it into the high voltage circuit without discharges of its own that could overlap the measurement.

The series has five models, each rated at 100 pF. IC100-.01 is rated for 100 kV and 50 to 400 Hz and is supplied on a base. IC200-.01, IC300-.01, IC400-.01 and IC500-.01 are rated for 200, 300, 400 and 500 kV at 50 to 60 Hz, and come on casters with a base, which makes them easier to move around the test hall.

Operation at 400 Hz is limited to 200 kV. For older partial discharge detectors, capacitors of 150 pF are offered.

The capacitors are used in laboratory and field tests of high voltage equipment insulation, alongside the partial discharge free coupling capacitors of the same range. The choice of model depends on the test voltage of the object, the source frequency and the number of measuring channels.

Technical specifications

Purposeintroducing a known PD pulse into an energised system
Capacitance100 pF (150 pF also offered for older detectors)
IC100-.01100 kV, 100 pF, 50 to 400 Hz, on a base
IC200-.01200 kV, 100 pF, 50 to 60 Hz, on casters with a base
IC300-.01300 kV, 100 pF, 50 to 60 Hz, on casters with a base
IC400-.01400 kV, 100 pF, 50 to 60 Hz, on casters with a base
IC500-.01500 kV, 100 pF, 50 to 60 Hz, on casters with a base
Operation at 400 Hzup to 200 kV only
Calibrator requiredCAL1C

Part numbers

Show all part numbers (5)

IC100-.01, IC200-.01, IC300-.01, IC400-.01, IC500-.01

Request a price and lead time

IC injection capacitors free of partial discharge, 100 to 500 kV, 100 pF, for calibrating PD measurements. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is needed to operate an injection capacitor?

A CAL1C PD calibrator. A multi-channel PD measurement system needs one capacitor per channel.

Which models work at 400 Hz?

IC100-.01 is rated for 50 to 400 Hz, while the other models are rated for 50 to 60 Hz. Operation at 400 Hz is limited to 200 kV.

Are capacitors with other capacitance available?

The standard models are rated 100 pF. For older partial discharge detectors, capacitors of 150 pF are offered.