
Calisto H1 Hydrogen Sensor for Transformer Oil, 25-5000 ppm, IP68, Modbus
A compact solid-state hydrogen sensor that mounts directly on the transformer and measures hydrogen in the oil continuously. It picks up spikes in hydrogen level that often point to an electrical fault and sends the readings over Modbus.
- Type
- solid-state hydrogen sensor in oil
- Measuring range
- 25-5000 ppm
- Accuracy
- 20% of reading or 25 ppm, whichever is greater
- Repeatability
- 10% of reading or 15 ppm, whichever is greater
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The H1 is aimed at transformers where a full online dissolved gas monitor is not economically justified, such as small distribution units, vault transformers, wind farm transformers, railway traction transformers and equipment on offshore platforms. By covering more assets with a single device, it gives a wider view of overall power system performance.
The sensing element is solid-state and sits directly in the oil, measuring hydrogen in real time. The housing is compact and rated IP68, with high resistance to electromagnetic and radio frequency interference. It works across a broad temperature range and withstands marine exposure. Because readings are continuous, fewer oil samples have to be taken on site, so staff spend less time beside a transformer in a potentially hazardous situation.
The measuring range runs from 25 to 5000 ppm. Accuracy is 20% of reading or 25 ppm, whichever is greater, and repeatability is 10% of reading or 15 ppm, whichever is greater. The response time is under 60 minutes to 90% of a step change, and cross-sensitivity to other gases such as CO, CO2 and hydrocarbons is below 2%.
The sensor has an isolated two-wire RS485 serial port running Modbus, and the user sets the device identifier. Its internal memory holds more than one year of data at hourly logging, with each record containing the hydrogen concentration and its rate of change. H1 data can be combined with readings from the manufacturer's other condition monitoring instruments and passed into its software platform for analysis. To collect data from several sensors, the manufacturer offers the N1 recorder, to which up to eight H1 sensors can be connected. The recorder powers them and shows the hydrogen concentration on its front display.
Technical specifications
| Type | solid-state hydrogen sensor in oil |
|---|---|
| Measuring range | 25-5000 ppm |
| Accuracy | 20% of reading or 25 ppm, whichever is greater |
| Repeatability | 10% of reading or 15 ppm, whichever is greater |
| Response time | under 60 minutes (90% of step change) |
| Cross-sensitivity | below 2% to other gases (CO, CO2, hydrocarbons) |
| Interface | isolated RS485, two-wire, Modbus |
| Device identifier | set by the user |
| Internal memory | more than 1 year of data, hourly logging |
| Ingress protection | IP68 |
| Installation | directly onto the transformer, sensing element in the oil |
Request a price and lead time
Calisto H1 Hydrogen Sensor for Transformer Oil, 25-5000 ppm, IP68, Modbus. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What is the measuring range and accuracy of the H1 sensor?
The range is 25-5000 ppm, with accuracy of 20% of reading or 25 ppm, whichever is greater.
How does the sensor send its data?
Through an isolated two-wire RS485 port using Modbus. Up to eight H1 sensors can be connected to the N1 recorder.
Is the sensor suitable for wind farms and offshore platforms?
Yes. It has IP68 protection and tolerates marine exposure and a wide temperature range, and the manufacturer lists wind farm transformers and offshore platforms among its applications.
Similar equipment from other manufacturers






