International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Protection relay test chassis F8200 with four F8 modules

The F8200 is a compact F8 series chassis that takes four interchangeable modules for single-phase and multi-phase testing of conventional, digital and hybrid protection schemes. It supports IEC 61850 and time synchronisation by GPS, IRIG-B and PTP.

Number of modules
up to four F8 modules
HVA voltage module
2 x 150 V @ 150 VA or 1 x 300 V @ 300 VA
HVA current module
2 x 25 A @ 150 VA; 50 A @ 300 VA in parallel
Transient current
up to 90 A @ 300 VA for 30 seconds

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The F8200 is used for protection testing in power generation, transmission and distribution. It carries out single-phase and multi-phase checks, tests of digital substations and hybrid digital-analogue schemes, and tests of reclosers, transducers and Class 2 meters.

The chassis holds up to four F8 modules in any arrangement. Modules are easy to swap, so the set can be reconfigured for new tasks by fitting different F8 modules. The HVA voltage module offers either 2 x 150 V @ 150 VA or 1 x 300 V @ 300 VA. The HVA current module has a pair of 25 A sources, each rated 150 VA; wired in parallel they give 50 A continuously at 300 VA, or up to 90 A at 300 VA for 30 seconds in transient mode, plus a 50 A DC output. The battery simulator delivers 6 to 300 V at 90 W, and the HD Logic I/O module provides eight pairs of inputs and outputs with two sockets each.

Timing and synchronisation support GPS, IRIG-B, PTP, USB and Ethernet over copper or optical links. For end-to-end tests with GPS synchronisation, the F8895 satellite antenna is connected to the command module port by a TNC cable. The antenna receives GPS, Galileo, BeiDou and GLONASS signals and has an IP67 housing.

The set conforms to IEC 61850 and works with the test procedures of Protection Suite v5 and RTS v7. Programmable coloured LED rings show the status of sources and contacts. For field work there are protective bumpers on the corners and edges plus carrying accessories, while for fixed installation the set mounts in 19-inch racks.

Technical specifications

Number of modulesup to four F8 modules
HVA voltage module2 x 150 V @ 150 VA or 1 x 300 V @ 300 VA
HVA current module2 x 25 A @ 150 VA; 50 A @ 300 VA in parallel
Transient currentup to 90 A @ 300 VA for 30 seconds
DC output50 A
Battery simulator6 to 300 V at 90 W
HD Logic I/O moduleeight pairs of inputs and outputs, two sockets each
Time synchronisationGPS, IRIG-B, PTP, USB, Ethernet (copper or optical)
CompatibilityIEC 61850, Protection Suite v5, RTS v7
Configurationportable with corner and edge bumpers, or 19-inch rack

Part numbers

Show all part numbers (1)

F8200

Request a price and lead time

Protection relay test chassis F8200 with four F8 modules. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which modules can be fitted in the F8200?

The chassis takes up to four F8 modules, for example the HVA voltage and current modules and the HD Logic I/O module, and the configuration changes by swapping modules.

What is the maximum current from the HVA current module?

It gives 50 A continuously at 300 VA when two sources are paralleled, and up to 90 A at 300 VA for 30 seconds in transient mode.

Can end-to-end tests with time synchronisation be run?

Yes, the set supports GPS, IRIG-B and PTP, and for GPS the F8895 antenna is connected to the command module.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides